...
首页> 外文期刊>Medicine. >Effect of different electrical stimulation protocols for pelvic floor rehabilitation of postpartum women with extremely weak muscle strength: Randomized control trial
【24h】

Effect of different electrical stimulation protocols for pelvic floor rehabilitation of postpartum women with extremely weak muscle strength: Randomized control trial

机译:不同电气刺激方案对产后女性骨髓骨骼恢复的影响极弱肌肉力量:随机对照试验

获取原文

摘要

Background: Pregnancy is one of the main risk factor of pelvic floor muscle dysfunction. Postpartum women with extremely weak muscle strength have difficulty to do voluntary pelvic floor muscle training. This study aims to evaluate the effects of different protocols of electrical stimulation in the treatment of postpartum women with extremely weak muscle strength. Methods: A total of 67 women were randomized into 2 groups: group A received transvaginal electrical stimulation (TVES) for 5 times, and group B received TVES for 3 times with electromyogram (EMG)-triggered neuromuscular stimulation twice. Subjects were evaluated before and after treatment. Pelvic muscle strength was measured by both digital vaginal palpation and EMG variables, and quality of life was investigated by 4 kinds of pelvic floor disease-related questionnaires. Results: According to the intention-to-treat principle, compared with baseline, in group A, EMG of contractile amplitude of endurance phase was significantly elevated ( P = .03), variation of contractile amplitude in tonic phase was more stable after treatment ( P = .004), and EMG of mean value of final rest was significantly elevated after treatment ( P = .047). After 5 times treatments, the incidence of correct pelvic floor muscle contraction in group A was significantly elevated ( P = .045). No significant difference of muscle strength test by digital vaginal palpation was detected between the 2 groups, so did questionnaires. Conclusion: For postpartum women with extremely weak muscle strength, TVES for 5 times might be more benefit for control ability of pelvic muscle contractions and elevating muscle strength even in short-time treatment.
机译:背景:怀孕是盆底肌功能功能障碍的主要风险因素之一。产后妇女具有极其弱的肌肉力量难以做自愿盆底肌肉训练。本研究旨在评估不同协议在肌肉力量极弱的产后妇女治疗中的影响。方法:将67名妇女随机分为2组:接受接受的经镜电刺激(TVES)5次,B组接受TVE与电灰度(EMG) - 触发神经肌肉刺激两次。在治疗之前和之后评估受试者。通过数字阴道触诊和EMG变量测量骨盆肌肉力量,并通过4种骨盆地板疾病相关问卷调查了生活质量。结果:根据意向治疗原理,与基线相比,在A组中,耐核相的收缩幅度显着升高(p = .03),治疗后滋补相的收缩振幅变化更稳定( P = .004),治疗后,最终休息的平均值的EMG显着升高(P = .047)。经过5次治疗后,A组A型骨盆肌收缩的发病率明显升高(P = .045)。在2组之间检测到通过数字阴道触觉肌肉强度试验没有显着差异,所以问卷。结论:对于肌肉强度极低的产后女性,TVES 5次可能会受益于盆腔肌肉收缩的控制能力,即使在短时间处理中也提高肌肉力量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号