Background The Attain Stability Quadripolar 4798 lead is a relatively new quadripolar active fixation coronary sinus (CS) lead. No cases of extraction of a chronically implanted 4798 lead have been published to date. Case summary A 52-year-old man with a history of previous cardiac resynchronization therapy pacemaker (CRT-P) insertion and atrioventricular node ablation presented to our institution with a pocket infection 69 weeks after implantation. Directed intravenous antibiotic therapy was commenced and an extraction was performed the following day. Extraction of the right atrial and right ventricular leads was simple and achieved with gentle manual traction. Extraction of the CS lead was more difficult. Significant traction was required due to the formation of adhesions inside the CS but extraction of the lead was eventually successful without complication. Specialized extraction equipment was not required. A new contralateral CRT-P device was implanted, and the patient was discharged home. He remains well at 3 months of follow-up. Discussion We present the first case of extraction of a chronically implanted active fixation Attain Stability Quadripolar lead. Our experience demonstrates that this has been performed successfully without specialist tools and with preservation of the CS branch. Significant adhesion was noted at the site of active fixation, however. Potential difficulty with this lead’s extraction should therefore be considered when contemplating its use.
机译:背景技术达到稳定性Quadripolar 4798铅是一种相对较新的四极管活性固定冠状动脉窦(CS)铅。迄今为止,没有公布长期植入的4798铅的提取情况。案例摘要A 52岁的男子患有先前心脏再同步治疗起搏器(CRT-P)插入和房室的节点消融,并在植入后69周呈现给我们的机构。开始指导静脉内抗生素治疗,并在第二天进行提取。右心房和右心室引入的提取简单,并通过温和的手动牵引实现。提取CS铅更困难。由于CS内部的粘连形成,需要显着的牵引力,但铅的提取最终是成功的而无需并发症。不需要专门的提取设备。植入了一种新的对侧CRT-P器件,患者排出回家。他在3个月的后续行动中仍然良好。讨论我们介绍了慢性植入的活性固定的第一种提取稳定性Quadripolar铅。我们的经验表明,没有专业工具,并保存CS分支,这已经成功地进行了成功。然而,在主体固定部位注意到显着的粘附性。因此,在考虑使用时,应考虑这种引线提取的潜在困难。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号