...
首页> 外文期刊>International Journal of Dentistry >A Simplified Prosthetic Implant Loading Protocol: 1-Year Clinical Follow-Up Study
【24h】

A Simplified Prosthetic Implant Loading Protocol: 1-Year Clinical Follow-Up Study

机译:一种简化的假肢植入式加载方案:1年临床后续研究

获取原文

摘要

Purpose. To retrospectively investigate the one-year clinical outcome following a standardized treatment protocol for immediate loading. The protocol mandates predefined requirements for implant stability. If fulfilled, immediate loading of the implants is performed with a simplified prosthetic protocol which includes one-time impression at the time of surgery and definitive restoration within eight weeks. Methods. Twenty-five patients were treated with 48 Neoss ProActive Tapered implants. Minimum primary stability was established before subjecting the implants to immediate nonfunctional load. Definitive prostheses were delivered six to eight weeks from implant placement. Insertion torque (IT), resonance frequency analysis (RFA), intraoral radiographs, and impressions of implant positions were registered at implant placement. During clinical follow-up, RFA was measured at two, four, and six to eight weeks and six months from implant placement to monitor continued implant stability. Marginal bone level measurements were performed at implant placement, six-month, and one-year follow-up visits. Results. IT was over 40?N·cm for 46 implants. Two implants with IT 30?N·cm were both splinted to another implant with IT 50?N·cm, tightening the retention screw with low forces. No implants were lost during the observation period. Mean RFA measurements remained stable without any decrease during the initial six-month healing phase. Mean marginal bone remodeling was ?0.47?±?0.38?mm from implant placement to 1 year. No significant difference was found for marginal bone remodeling between implants placed in the healed bone or fresh extraction sockets. Conclusion. Within the limits of this study, it is concluded that using a simplified immediate loading protocol can be predictably applied to reduce the overall treatment time and the number of clinical sessions.
机译:目的。回顾性地调查标准化治疗方案后的一年临床结果以立即载入。该协议要求植入稳定性的预定义要求。如果满足的话,用简化的假体协议进行植入物的立即加载,其包括在手术时的一次性印象,并且在八周内恢复。方法。用48个神奈主动锥形植入物治疗二十五名患者。在使植入物进行即时无官能载荷之前建立最小初级稳定性。从植入物放置六至八周的明确假体。插入扭矩(IT),共振频率分析(RFA),内部射线照相和植入位置的印迹在植入物位置登记。在临床随访期间,RFA在植入物放置到植入物稳定性的植入物稳定性中测量RFA。边缘骨水平测量是在植入物安置,六个月和一年的后续访问中进行的。结果。 46个植入物超过40?n·cm。两个植入物<30?N·n·cm都夹在另一个植入物中,用它>50Ω·n·cm,用低力拧紧保持螺钉。观察期内没有植入物丢失。在最初的六个月愈合阶段,平均RFA测量保持稳定而不会在初始六个月的愈合阶段下降。平均边缘骨重塑是?0.47?±0.38?mm从植入物放置到1年。发现植入物或新鲜提取插座中的植入物之间的边缘骨重塑没有显着差异。结论。在本研究的局限质内,得出结论,可以使用简化的立即加载方案来预测地应用以减少整个治疗时间和临床会话的数量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号