TruNatomy (TN; Dentsply Sirona, Maillefer, Ballaigues, Switzerland) is a newly released system that was not tested in any previous studies. The objective of this work is to evaluate cyclic fatigue resistance of the new file and compare it with the Twisted Files (TF) and ProTaper Next (PTN). Forty-five files were distributed into 3 groups: PTN X2 (size 25 and taper 0.06), TF (size 25 and taper 0.06), and TN prime file (size 26 and taper 0.04). Each group included 15 files. Lengths of all files were 25?mm. Cyclic fatigue testing was done using artificial stainless-steel canals with 60-degree curvature and 5?mm radius. Continuous rotation movement at 300?rpm was used until the file fractures. Time for file separation was recorded in seconds. The number of cycles to failure (NCF) mean and standard deviation for each group was calculated. For statistical analysis of data, ANOVA and Tukey’s multiple comparison test were used. Mean and standard deviation (SD) of NCF were 259?±?37.2, 521.67?±?63.07 and 846.67?±?37.16 for PTN, TF, and TN respectively. TN on average had significantly the highest NCF compared with PTN (p0.05) and TF (p0.05). TruNatomy file showed superior cyclic fatigue resistance. With its potential to preserve tooth structure, this file offers a good cyclic fatigue advantage. However, future studies are required to evaluate other properties of this file and to examine its clinical performance.
机译:Trunatomy(TN; Lentsply Sirona,Maklefer,Ballaigues,瑞士)是一个新发布的系统,在以前的任何研究中都没有测试过。这项工作的目的是评估新文件的循环疲劳电阻,并将其与扭曲文件(TF)和propaper进行比较(PTN)。四十五个文件分配到3组:PTN X2(尺寸25和锥度0.06),TF(尺寸25和锥度0.06)和TN填充(尺寸26和锥度0.04)。每个组都包含15个文件。所有文件的长度为25?mm。使用具有60度曲率的人工不锈钢管和5Ωmm半径进行循环疲劳试验。在300℃下连续旋转运动在文件骨折之前使用。在几秒钟内记录文件分离的时间。计算失败的循环次数(NCF)均值和每个组的标准偏差。对于数据的统计分析,使用ANOVA和Tukey的多重比较测试。 NCF的平均值和标准偏差(SD)分别为259°(SD)为259°?±37.2,521.67?±63.07和846.67?±37.16,分别用于PTN,TF和TN。平均TN与PTN(P <0.05)和TF相比明显最高的NCF(P <0.05)。 Trunatomy文件显示出卓越的循环疲劳性。凭借其保护牙齿结构的潜力,该文件提供了良好的循环疲劳优势。但是,未来的研究是评估此文件的其他性质并检查其临床表现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号