首页> 外文期刊>International Journal of Photoenergy >Study on the Improved Electrical and Thermal Performance of the PV/T Fa?ade System
【24h】

Study on the Improved Electrical and Thermal Performance of the PV/T Fa?ade System

机译:PV / T FA的改进电气和热性能研究

获取原文
   

获取外文期刊封面封底 >>

       

摘要

This paper is aimed at improving the performance of a building-integrated photovoltaic thermal (BIPV/T) system driven by a refrigerant pump. The research is aimed at optimizing and upgrading the BIPV/T system to address the shortcomings of the original system by replacing roll-bond PV/T units with improved heat transfer features. The system’s connecting form was redesigned using a liquid separator to solve the uneven distribution of the refrigerant on the PV/T fa?ade. We proposed the variable frequency refrigerant pump that can be adjusted to suit the working condition. An experimental study was performed to analyze the electrical and thermal efficiency of the proposed system. The results show that the electrical efficiency of the BIPV/T system was 8% which is 14.3% higher than the traditional BIPV system, while in the test period, the BIPV/T system average COP was 3.4. The thermal and comprehensive efficiencies were 20% and 42%, respectively. Besides, the proposed system’s average COP was 3.7 times greater than the original BIPV/T system.
机译:本文旨在提高由制冷剂泵驱动的建筑集成光伏热(BIPV / T)系统的性能。该研究旨在优化和升级BIPV / T系统,通过更换具有改进的传热功能的滚动PV / T单元来解决原始系统的缺点。使用液体分离器重新设计系统的连接形式,以解决PV / T FA的制冷剂的不均匀分布。我们提出了可调节的可变频率制冷剂泵以适应工作状态。进行实验研究以分析所提出的系统的电气和热效率。结果表明,BIPV / T系统的电效率为8%,比传统的BIPV系统高14.3%,而在测试期间,BIPV / T系统平均COP为3.4。热和综合效率分别为20%和42%。此外,所提出的系统的平均COP比原始BIPV / T系统大3.7倍。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号