首页> 外文期刊>International Journal of Power Electronics and Drive Systems >THD performance of single phase five level inverter using proportional resonant and harmonic compensators current controller
【24h】

THD performance of single phase five level inverter using proportional resonant and harmonic compensators current controller

机译:使用比例谐振和谐波补偿器电流控制器的单相五电平逆变器的性能

获取原文
           

摘要

This paper observe the total harmonic distortion (THD) performance of single phase five level inverter using proportional resonant (PR) and harmonic compensators current controller. The THD when adding PR current controller was 1.6% at first. After more functions were added to the PR current controller to reduce the THD at the 3suprd/sup, 5supth/sup and 7supth/sup harmonic orders, the THD of the 3suprd/sup harmonic order was reduced from 0.45% to 0.1% while the 5supth/sup and 7supth/sup harmonic orders were reduced from 0.6% and 0.43% to 0.25% and 0.4% respectively. The development and simulation is performed using Matlab/Simulink. The simulation result is performed by using Fast Fourier Transform analysis (FFT) for the harmonics captured.
机译:本文使用比例谐振(PR)和谐波补偿器电流控制器,观察单相五电平逆变器的总谐波失真(THD)性能。添加PR当前控制器时的THD首先是1.6%。在将更多功能添加到PR电流控制器后,以减少3 Rd ,5 th 和7 th 谐波订单,thd在3 Rd 谐波阶减少0.45%至0.1%,而5 th 和7 th 谐波序列从0.6%降低0.43%至0.25%和0.4%。使用MATLAB / SIMULINK执行开发和仿真。模拟结果是通过使用捕获的谐波的快速傅里叶变换分析(FFT)来执行。