Introduction: The removal of an encrusted nephrostomy tube can be a challenging maneuver. Urological literature is very bare in detailing techniques for removal of entrapped percutaneous catheters. We present a simple, safe and non-invasive technique of nephrostomy removal using a vascular introducer sheath, useful to manage complicated situations such as nephrostomies blocked for severe encrustations or disabled in their self-locking system. Surgical technique: The nephrostomy tube is cut and the stump is passed with a suture needle. The suture is passed through the inner vascular introducer sheath tip, and the introducer is then removed. The introducer sheath is advanced over the nephrostomy until joining the pigtail segment, under fluoroscopy guidance. Thus the suture is pulled out with strenght to contrast the opposite stiffness of the encrusted coil, until the nephrostomy has safely come out. Comment: The sheath exchange technique is quick, involves less manipulation through the perirenal fascia and kidney, and is suitable for different conditions of entrapped nephrostomies.
机译:简介:去除覆盖的尼弗鲁托尤管可能是一个具有挑战性的机动。泌尿外文文献在详细说明用于去除捕获的经皮导管的技术方面非常裸露。我们使用血管导引器护套提出了一种简单,安全和非侵入性的肾坏细术拆除技术,可用于管理诸如肾坏组织的复杂情况,例如在其自锁系统中禁用肾坏固术。手术技术:切割肾坏热管,树桩通过缝合针。缝合线通过内部血管引入鞘尖端,然后移除导引器。导引器护套在肾病术后,在透镜引导下加入猪尾片段之前。因此,缝合线用力拉出,以对比镶嵌线圈的相反刚度,直到肾病术安全地出现。评论:鞘交换技术很快,涉及通过脑梗死筋膜和肾脏的操作减少,并且适用于陷阱肾脏术的不同条件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号