首页> 外文期刊>Arid Zone Journal of Engineering, Technology and Environment >Impact of Climate Change on the Design Parameters of Heating, Ventilation and Air Conditioning Systems for Manned Spacecraft
【24h】

Impact of Climate Change on the Design Parameters of Heating, Ventilation and Air Conditioning Systems for Manned Spacecraft

机译:气候变化对载人航天器供暖,通风和空调系统设计参数的影响

获取原文
       

摘要

Climatic design information has been published for several locations in the world by American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) but there has not been data for Nigerian cities in these publications. Therefore, this study was embarked upon to bridge the gap in knowledge. The study of impact of climate change on the design parameters of Heating, Ventilation and Air Conditioning (HVAC) systems for spacecraft cabin environment is presented with particular focus on Ikeja-Lagos, Nigeria. Firstly, the characteristics climate parameters such as outdoor dry-bulb temperature, coincident wet-bulb temperature, relative humidity, pressures, air composition, among others as it affects manned spacecraft were discussed. The data for climatic parameters for Ikeja-Lagos, Nigeria, for a period of fifteen years (1995-2009) were obtained from Nigerian Meteorological Agency (NIMET), Oshodi-Lagos. Statistical data and Microsoft excel were used for evaluation of variation trends of the climate parameters for departure city. This is very important in determining thermal human comfort in spacecrafts on ascent. Results obtained from this study are hereby presented. The Ikeja-Lagos dry-bulb temperature average results obtained were 33.81°C, 32.98°C, 32.3°C, 22.1°C, 21.19°C, 20.43°C, 23.84°C and 31.65oC.at 0.4%, 1.0%, 2.0%, 97.5%, 99.0%, 99.6%, median of extreme lows and median of extreme highs, respectively. The Ikeja-Lagos relative humidity average results were 116.3, 112.65, 109.14, 99.83 and 49.42 at 0.4%, 1% and 2.0% occurrence as well as at median of extreme highs and median of extreme lows, respectively. Ikeja-Lagos had mean coincident dry bulb temperature of 33.81°C and 32.98°C at 0.4% and 1% percentile respectively. The dry bulb temperature for Ikeja-Lagos was determined to be an average range from 20.43°C to 22.1°C between January to December, in the period of 1995-2009, at 97.5% 99% and 99.6% percentile respectively. These results provide values of design parameters which are useful in the design of HVAC for space crafts with climate change adequately taken into consideration as it applies to Ikeja-Lagos, Nigeria
机译:通过美国供暖,制冷和空调工程师(ASHRAE)的世界上几个地点公布了气候设计信息,但这些出版物中没有尼日利亚城市的数据。因此,这项研究开始弥合知识中的差距。气候变化对航天器舱室环境的加热,通风和空调(HVAC)系统的设计参数的影响,特别关注Ikeja-Lagos,尼日利亚。首先,讨论了诸如室外干泡温度,重合湿泡温度,相对湿度,压力,空气组合物的特征,等等,因此讨论了其影响载人的航天器。从尼日利亚气象学机构(Nimet),奥什迪 - 拉各斯获得了十五年(1995-2009)的Ikeja-Lagos气候参数的数据。统计数据和Microsoft Excel用于评估出发城市气候参数的变化趋势。这对于在上升时确定航天器中的热人舒适性非常重要。特此提出了本研究获得的结果。获得的Ikeja-Lagos干灯泡温度平均结果为33.81℃,32.98℃,32.3℃,22.1℃,21.19℃,20.43℃,23.84°C和31.65oc.AT 0.4%,1.0%, 2.0%,97.5%,99.0%,99.6%,极端低位中位数和极端高位的中位数。 IKEJA-LAGOS的相对湿度平均结果分别为116.3,112.65,109.14,99.83和49.42,分别为0.4%,1%和2.0%以及极端高位和极端中位数的中位数。 Ikeja-Lagos分别具有33.81°C和32.98°C的重合干燥泡温度分别为0.4%和1%百分位。 1995 - 2009年1月至12月,Ikeja-Lagos的干灯泡温度确定为20.43°C至22.1°C,分别为97.5%99%和99.6%百分位。这些结果提供了设计参数的价值,可用于HVAC的空间工艺设计,气候变化充分考虑,因为它适用于Ikeja-Lagos,尼日利亚

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号