首页> 外文期刊>Air, Soil and Water Research >Assessment of Airborne Culturable Fungal Load in an Indoor Environment of Dormitory Rooms The Case of University of Gondar Student’s Dormitory Rooms, Northwest Ethiopia
【24h】

Assessment of Airborne Culturable Fungal Load in an Indoor Environment of Dormitory Rooms The Case of University of Gondar Student’s Dormitory Rooms, Northwest Ethiopia

机译:评估宿舍间室内环境中的空气传播的培养真菌载荷大学戈尼尔学生宿舍间,西北埃塞俄比亚的案例

获取原文
       

摘要

Pollution caused by fungal contamination on building materials contributes to poor indoor air quality. Fungi are known to cause several health-related problems, such as acute toxicity, hypersensitivity, invasive mycoses, and respiratory problems. Thus, this study aimed to determine the load and diversity of airborne culturable fungi in the dormitory rooms. An institution-based cross-sectional study was conducted from March to June 2019 at the University of Gondar students’ dormitory rooms. Statistical analyses were carried out using Stata/SE 14.0. Spearman ranks correlation was used to assess the correlation of fungal load with indoor physical parameters. The median fungal loads were 250 CFU/m~(3) and 157 CFU/m~(3) in the morning and afternoon, respectively. Most commonly identified fungal genera/species were Aspergillus, Penicillium, Alternaria, Fusarium, Candida, Trichophyton, Piedraia, Microsporum, Geotrichum, Saccharomyces, Rhodotorula, Rhizopus, Exophiala, Arthroderma, Cladosporium, Gliocladium , and Botrytis . Formaldehyde (r ?=??0.2859, P ?=?.0031), temperature (r ?=??0.2153, P ?=?.0274), and CO_(2) (r ?=??0.3785, P ?=?.0001) were negatively correlated with airborne indoor fungal load in the morning and CO_(2) (r ?=?0.3183, P ?=?.0009) and temperature (r ?=?0.2046, P ?=?.0363) positively correlated with airborne indoor fungal load in the afternoon. As a conclusion, the airborne fungal load in the dormitory room was intermediate according to the European standard of nonindustrial premises. Substantial action should be taken to reduce the fungal contamination of indoor environments.
机译:真菌污染对建筑材料造成的污染有助于室内空气质量差。已知真菌造成若干健康相关的问题,例如急性毒性,超敏反应,侵袭性肌肉和呼吸问题。因此,本研究旨在确定宿舍间空中培养真菌的负荷和多样性。基于机构的横断面研究是从2019年3月到2019年6月在戈内尔大学宿舍间的宿舍间的横断面研究。使用STATA / SE 14.0进行统计分析。 Spearman排名相关性用于评估真菌载荷与室内物理参数的相关性。中间的真菌载荷分别在早晨和下午分别为250分CFU / m〜(3)和157 CFU / M〜(3)。最常见的真菌属/物种是曲霉,青霉素,alertaria,镰刀菌,念珠菌,毛癣菌,皮埃拉菊,微孢子菌,地产曲线,酿酒酵母,rhodotorula,根瘤菌,exoshiala,亚蒽酚,囊孢子,gliocladium和 botrytis。甲醛( r?= 0.2859, p?=α.0031),温度( r?= 0.2153, p?=Δs.0274)和co_(2 )( r?= = ?? 0.3785, p?=Δ0001)与早晨和CO_(2)( r?= 0.3183, p?= 0009)和温度( r?=Δ= 0.2046, p?=Δ.0363)在下午与空气中的室内真菌载荷呈正相关。作为结论,宿舍间的空气载体载荷根据欧洲非工业处所标准中级。应采取实质性行动来减少室内环境的真菌污染。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号