Purpose: To evaluate the efficacy of treating patients with +3.00 diopters (D) to +6.00 D of hyperopia via laser-assisted in situ keratomileusis (LASIK) with the WaveLight Allegretto 400?and EX500 excimer laser systems. Setting: Private clinical ophthalmology practice. Patients and methods: This was a retrospective study of patients undergoing LASIK treatments of +3.00 to +6.00 D on two different WaveLight laser systems: 163 eyes on the 400 (Hertz) Hz system and 54 eyes on the 500 Hz system. The duration of follow-up was 6 months postoperation. Data were evaluated for uncorrected distance visual acuity, corrected distance visual acuity (CDVA), spherical equivalents (SEQs), and changes in these parameters (eg, loss of vision, regression over time). Results: Treatment with both lasers was safe and effective, with loss of one line of CDVA in four of 162 eyes using the 400 Hz laser system, and none of the 54 eyes with the 500 Hz laser system. Overall, regression ≥0.75 D from goal at 6 months was observed in 11.7% (19/163) of eyes in the 400 Hz laser group and 9.26% (5/54) of eyes in the 500 Hz laser group (regression ≥0.50 D =77.9% [127/163] and 77.8% [42/54], respectively). The mean SEQ regressions for all eyes with moderate hyperopia were 0.10 and 0.18 D for those with high hyperopia. Conclusions: Both the 400 and 500 Hz excimer laser systems were safe and effective for the LASIK treatment of moderate-to-high hyperopia. The overall rate of regression was low and the amount of regression was relatively small with both systems.
机译:目的:通过激光辅助用Wawelight Allegretto 400,评估治疗+ 3.00屈光度(d)+6.00d的+6.00d的+6.00d +6.00d的疗效。和EX500准分子激光系统。环境:私人临床眼科实践。患者和方法:这是在两种不同的Wavel激光系统上进行+ 3.00至+6.00d +3.00至+6.00d的患者的回顾性研究:163只眼睛在400(赫兹)Hz系统上和500 Hz系统上的54只眼睛。后续持续时间为6个月的术后。评估数据的未校正距离视敏度,校正距离视力(CDVA),球面等同物(SEQS),以及这些参数的变化(例如,vision丢失,回归而随时间的回归)。结果:双激光治疗安全有效,使用400 Hz激光系统,在162只眼中的四个CDVA中丧失,损失了54只HZ激光系统。总体而言,在400Hz激光组的11.7%(19/163)中,在400Hz激光组的11.7%(19/163)和500Hz激光组中的眼中的11.7%(第5/54)(5/54)(回归≥0.50d分别为77.9%[127/163]和77.8%[42/54]。具有中等远视的所有眼睛的平均SEQ回归为高远远率为0.10和0.18d。结论:400和500 Hz准分子激光系统都是安全有效的,对于中等至高远程的LASIK治疗。回归的总体速率低,两种系统的回归量相对较小。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号