首页> 外文期刊>Brazilian Journal of Physical Therapy >Dynamometry for the measurement of grip, pinch, and trunk muscles strength in subjects with subacute stroke: reliability and different number of trials
【24h】

Dynamometry for the measurement of grip, pinch, and trunk muscles strength in subjects with subacute stroke: reliability and different number of trials

机译:用于测量具有亚克斯语中风的受试者的握把,夹和躯干肌肉力量的动力学:可靠性和不同的试验数量

获取原文
           

摘要

Background Muscle strength is usually measured in individuals with stroke with Portable dynamometers (gold standard). However, no studies have investigated the reliability, the standard error of measurement (SEM) and the minimal detectable difference (MDD95%) of the dynamometry for the measurement of hand grip, pinch grip and trunk strength in subjects with subacute stroke. Objective 1) To investigate the intra and inter-rater reliability, the SEM and the MDD95% of the portable dynamometers for the measurement of grip, pinch and trunk strength in subjects with subacute stroke, and 2) to verify whether the use of different number of trials (first trial and the average of the first two and three trials) affected the results. Method 32 subjects with subacute stroke (time since stroke onset: 3.6 months, SD=0.66 months) were evaluated. Hand grip, 3 pinch grips (i.e. pulp-to-pulp/palmar/lateral) and 4 trunk muscles (i.e. flexors, extensors, lateral flexors and rotators) strength were bilaterally assessed (except trunk flexors/extensors) with portable dynamometry by two independent examiners over two sessions (1-2 weeks apart). One-way ANOVAs and intraclass correlation coefficients (ICC2,k) were used for analysis (α=0.05). SEM and MDD95% were also calculated. Results For all muscular groups and sources of outcome values, including one trial, after familiarization, similar results were found (0.01≤F≤0.08; 0.92≤p≤0.99) with significant and adequate values of intra-rater (0.64≤ICC≤0.99; 0.23≤95%CI≤0.99) and inter-rater (0.66≤ICC≤0.99; 0.25≤95%CI≤0.99) reliability. SEM and MDD95% were considered low (0.39≤EPM≤2.21 Kg; 0.96≤MMD95%≤6.12 Kg) for all outcome scores. Conclusion Only one trial, following familiarization, demonstrated adequate intra-rater and inter-rater reliability of the portable dynamometers for the measurement of hand grip, pinch grip and trunk strength in subjects with subacute stroke.
机译:背景技术肌肉强度通常用卒中的个体测量,用便携式测量仪(金标准)。然而,没有研究已经研究了测量的可靠性,测量标准误差(SEM)和测量的测量的最小可检测差(MDD95%),用于测量具有亚急性行程的受试者中的手柄,夹紧抓地力和躯干强度。目的1)研究便携式测量器的帧内和帧间间可靠性,SEM和MDD95%,用于测量具有亚急性行程的受试者的抓地力,捏合和躯干强度,以及2)以验证是否使用不同的数量审判(第一次试验和前两三和三项试验的平均)影响了结果。方法32评估亚急性中风的受试者(自中风发病的时间:3.6个月,SD = 0.66个月)。手动握把,3个夹紧夹具(即纸浆到纸浆/露珠/侧面)和4个躯干肌肉(即屈肌,伸肌,横向屈肌和旋转器)强度,双侧评估(后备箱屈肌/伸肌),通过两个独立的便携式动力学两次会议(分开1-2周)的审查员。单向ANOVA和胃部相关系数(ICC2,K)用于分析(α= 0.05)。还计算了SEM和MDD95%。熟悉相似结果的所有肌肉群和结果值的结果(包括一项试验)(0.01≤F≤0.08;0.92≤p≤0.99),具有显着且足够的内部rater值(0.64≤cix0.99 ;0.23≤95%CI≤0.99)和帧间帧间(0.66≤0.99;0.25≤95%CI≤0.99)可靠性。 SEM和MDD95%被认为是低(0.39≤pm≤2.21公斤;所有结果评分为0.96≤mmd95%≤6.12千克)。结论熟悉后,只有一项试验表明了便携式测量仪的足够的帧内计和帧间可靠性,用于测量具有亚急性行程的受试者的手势握把,捏捏和躯干强度。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号