Evaluation of a self-retaining distractor for hip joint arthroscopy in toy breed dogs

机译:对玩具品种犬髋关节关节镜检查的自我保留分散镜的评价

获取原文
       

摘要

Hip arthroscopy has become a viable option over the last few years for small animal orthopedic diseases, including hip dysplasia, osteoarthritis, and joint evaluation. However, the narrow joint spaces make it difficult to manipulate the instrument, and depth of tissues make it difficult to distract the joint space. In addition, it is very difficult to maintain consistent distraction over time with a manual distraction due to hand fatigue. To overcome these difficulties, distractors are used in human medicine to improve safety and accuracy of arthroscopy. Therefore, in this study, distractor devices were applied to hip joints in small toy breed dogs to evaluate their technical efficacy. Potential iatrogenic neurovascular and articular damage were also evaluated by comparing two techniques for performing hip joint arthroscopy: the self-retaining distractor and external manipulation. The mean?±?SD of the joint distraction distance was 8.88?±?3.54?mm in the self-retaining distraction group and 2.37?±?0.82?mm in the manual traction group. As the joint space increased, surgeons could more easily place an arthroscopy portal and more comfortably manipulate the instrument with a distractor device. Furthermore, the acetabular cartilage damage (p?=?0.004) was significantly greater in the external manipulation group, but articular damage to the femoral head (p?=?0.940) was similar in both groups. The results of this study revealed that use of a distractor device can be a viable option for performing hip arthroscopy in small animals. The device significantly improved the surgeon's performance without surgical assistance, and it reduced iatrogenic cartilage damage compared with manual traction. Further study is needed to quantify neurapraxia associated with distractor placement.
机译:髋关节视镜检查过去几年已成为一种可行的选择,适用于小动物骨科疾病,包括髋关节发育不良,骨关节炎和联合评估。然而,狭窄的关节空间使得难以操纵仪器,并且组织的深度使得难以分散联合空间的注意力。此外,由于手疲劳,非常难以随着时间的推移保持一致的分心。为了克服这些困难,分散剂用于人体医学,以提高关节镜的安全性和准确性。因此,在这项研究中,将分散的器件应用于小型玩具品种狗的髋关节,以评估其技术效果。通过比较用于进行髋关节关节镜检查的两种技术,还通过比较了两种技术来评估潜在的性能性神经血管和关节损伤:自我保留的腕表和外部操纵。平均值θ±sd的平均分散距离为8.88?±3.54Ω·mm,在手动牵引组中的2.37?±0.82?mm。随着关节空间的增加,外科医生可以更容易地放置关节镜,并更舒适地操纵仪器用牵引器装置。此外,在外部操纵组中,髋臼软骨损伤(p?= 0.004)显着更大,但对股骨头的关节损伤(p?= 0.940)在两组中相似。该研究的结果表明,使用牵引装置的使用可以是在小动物中进行髋关节镜检查的可行选择。该器件在没有手术辅助的情况下显着提高了外科医生的性能,而且与手动牵引相比,它降低了成原性的软骨损伤。需要进一步研究来量化与患者放置相关的神经毛细血管。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号