In this paper the authors describe in detail the exposure limit values concerning artificial optical radiation due to the main incoherent light sources found in offices. In particular, for some examples of significant sources chosen as case studies, we discuss the results of in situ measurements of the exposure values using a broadband photoradiometer. By comparing the measurement results with the exposure limit values specified in the European legislation, the maximum exposure times for workers have been evaluated. From the analysis of the results it can be concluded that the lighting sources typically present in indoor workplaces under usual conditions of use, do not pose a health risks for workers. However, in the case of accidental exposure during work activities or exposure linked to maintenance activities (short exposure distance), values in excess of the limit values have been observed, with decidedly short maximum exposure times.
机译:在本文中,作者详细描述了由于在办公室中发现的主要不连贯光源而有关人造光学辐射的曝光极限值。特别是,对于选择作为案例研究的重要来源的一些例子,我们使用宽带光学计讨论了曝光值的原位测量结果。通过将测量结果与在欧洲立法中规定的曝光极限值进行比较,已经评估了工人的最大曝光时间。从分析结果,可以得出结论,通常在通常使用条件下通常存在的照明源在室内工作场所中,对工人来说不会对健康风险提出造成健康风险。然而,在与维护活动的工作活动或接触期间发生意外暴露(短曝光距离)时,已经观察到过量限制值的值,具有明显的最大曝光时间。