摘要

The DC fault protection is one of the main issues in multi-terminal voltage source converter based high-voltage direct current (VSC–MTDC) transmission systems. In this study, a DC short-circuit fault ride-through method for full-bridge modular multi-level converter (FB-MMC) based MTDC systems is proposed. First, the model of the FB-MMC topology is analysed. Then, the principle of fault current clearing in full-bridge sub-module (FB-SM) is introduced. The converter protection control strategy and the system protection scheme are proposed, benefitting from the capability of quick fault current elimination with the valves blocked using the FB-MMC topology. With this method, the MTDC system could restart quickly after clearance of DC fault without cutting off the AC grid. The proposed protection strategy is demonstrated using the simulation model in PSCAD/EMTDC. Simulation results verify the feasibility and effectiveness of the strategy.
机译:直流故障保护是基于多端电压源转换器的高压直流(VSC-MTDC)传输系统的主要问题之一。在本研究中,提出了一种用于全桥模块化多电平转换器(FB-MMC)的MTDC系统的DC短路故障方法。首先,分析了FB-MMC拓扑的模型。然后,介绍了全桥子模块(FB-SM)中的故障电流清除原理。提出了转换器保护控制策略和系统保护方案,利用使用FB-MMC拓扑的阀门堵塞快速故障电流消除的能力。通过这种方法,MTDC系统可以在间接在DC故障的间隙后快速重启,而不会切断AC电网。使用PSCAD / EMTDC中的仿真模型演示了所提出的保护策略。仿真结果验证了策略的可行性和有效性。