Evaluation of an Electronic Periodontal Probe Versus a Manual Probe

机译:电子牙周探针与手动探针的评估

获取原文
获取外文期刊封面目录资料

摘要

Introduction: Diagnosis of periodontal diseases requires reco-rding of clinical and periodontal variables. Possible measurement errors in recording the periodontal findings are dependent on the measurement method.Aim: The purpose of the trial was to investigate an electronic, pressure-calibrated probe compared with a standard, manual measurement probe used to take periodontal variables.Materials and Methods: The study included 25 subjects suffering from periodontal disease. Their findings were taken by two users on a randomized basis using a standard probe and an electronic, pressure calibrated probe, at an interval of 24 hours. The recorded clinical variables contained Pocket Depth (PD), Attachment Level (AL), Bleeding on Probing (BOP), the complete time needed to take the findings and the sensation of pain experienced by a Visual Analogue Scale (VAS). The data were statistically analyzed using the paired t-test.Results: The measurement values (24 patients) for PD (p=0.03) and BOP (p=0.01) indicated a significant difference (paired t test, p>0.05), while there was no statistical difference for AL (p=0.064). A classification of PD into groups of 1-3mm, 4-6mm and =7mm showed that the manual method measured higher values than the electronic method (p=0.001). The measurement values did not reveal any significant differences (p>0.05) with respect to the total time needed to take findings and the measurement time for PD/AL. There was a significant difference (Wilcoxon-test, p<0.05) in VAS values (p=0.048) and in terms of the time needed to record the findings for BOP (p=0.004).Conclusion: It can be assumed that the electronic probe should mainly be used in the supportive periodontal therapy. Present study showed that the use of a standard manual probe is essential to review conspicuous or unclear measurement values, or when treating deep pockets higher than 7mm.
机译:简介:牙周疾病的诊断需要记录临床和牙周变量。记录牙周发现结果时可能出现的测量误差取决于测量方法。目的:该试验的目的是研究一种压力校准电子探头与用于测量牙周变量的标准手动测量探头的对比。该研究包括25名患有牙周疾病的受试者。他们的发现是由两个用户随机使用标准探头和电子压力校准探头在24小时间隔内随机获取的。记录的临床变量包括口袋深度(PD),依恋水平(AL),探查出血(BOP),进行发现所需的完整时间以及视觉模拟量表(VAS)所经历的疼痛感。结果:配对PD检验(p = 0.03)和BOP(p = 0.01)的测量值(24例)显示出显着性差异(配对t检验,p> 0.05),而AL之间无统计学差异(p = 0.064)。将PD分为1-3mm,4-6mm和= 7mm组,结果表明手动方法测得的值高于电子方法(p = 0.001)。在获得发现所需的总时间和PD / AL的测量时间方面,测量值未显示任何显着差异(p> 0.05)。 VAS值(p = 0.048)和记录BOP结果所需的时间(p = 0.004)有显着差异(Wilcoxon检验,p <0.05)。结论:可以假设电子探头应主要用于牙周支持治疗。当前的研究表明,使用标准的手动探针对于查看明显或不清楚的测量值,或者在治疗大于7mm的深袋时至关重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号