首页> 外文期刊>Journal of Clinical Microbiology >Performance of the GeneXpert CT/NG Assay Compared to That of the Aptima AC2 Assay for Detection of Rectal Chlamydia trachomatis and Neisseria gonorrhoeae by Use of Residual Aptima Samples
【24h】

Performance of the GeneXpert CT/NG Assay Compared to That of the Aptima AC2 Assay for Detection of Rectal Chlamydia trachomatis and Neisseria gonorrhoeae by Use of Residual Aptima Samples

机译:GeneXpert CT / NG分析与Aptima AC2分析相比使用残留的Aptima样品检测直肠沙眼衣原体和淋病奈瑟菌的性能

获取原文
           

摘要

There are currently no commercially available molecular assays for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in rectal swabs with regulatory approval. We compared the Cepheid GeneXpert CT/NG assay with the GenProbe Aptima Combo2 assay, using 409 rectal swabs. Using Aptima as the gold standard, the sensitivity, specificity, and positive and negative predictive values of GeneXpert for the detection of C. trachomatis and N. gonorrhoeae were 86%, 99.2%, 92.5%, and 98.4% and 91.1%, 100%, 100%, and 98.6%, respectively. Despite significant dilution of samples prior to GeneXpert testing, the assay performed well with excellent specificity.
机译:目前尚无经监管机构批准可用于检测直肠拭子中沙眼衣原体和淋病奈瑟氏球菌的商业化分子检测方法。我们使用409个直肠拭子比较了Cepheid GeneXpert CT / NG分析与GenProbe Aptima Combo2分析。以Aptima作为金标准,GeneXpert检测沙眼衣原体和淋病奈瑟氏球菌的敏感性,特异性以及阳性和阴性预测值分别为86%,99.2%,92.5%和98.4%,91.1%,100% ,100%和98.6%。尽管在GeneXpert测试之前样品已大量稀释,但该检测方法仍具有出色的特异性,表现良好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号