首页> 外文期刊>Journal of Clinical Microbiology >Performance of Two Resin-Containing Blood Culture Media in Detection of Bloodstream Infections and in Direct Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry (MALDI-TOF MS) Broth Assays for Isolate Identification: Clinical Comparison of the BacT/Alert Plus and Bactec Plus Systems
【24h】

Performance of Two Resin-Containing Blood Culture Media in Detection of Bloodstream Infections and in Direct Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry (MALDI-TOF MS) Broth Assays for Isolate Identification: Clinical Comparison of the BacT/Alert Plus and Bactec Plus Systems

机译:两种含树脂的血液培养基在检测血流感染和直接基质辅助激光解吸电离中的性能–飞行时间质谱(MALDI-TOF MS)肉汤测定法用于分离物鉴定:BacT / Alert Plus和BacT / Alert Plus的临床比较Bactec Plus系统

获取原文
           

摘要

We compared the clinical performances of the BacT/Alert Plus (bioMérieux) and Bactec Plus (Becton Dickinson) aerobic and anaerobic blood culture (BC) media with adsorbent polymeric beads. Patients ≥16 years old with suspected bloodstream infections (BSIs) were enrolled in intensive care units and infectious disease wards. A single 40-ml blood sample was collected from each and used to inoculate (10 ml/bottle) one set of BacT/Alert Plus cultures and one set of Bactec Plus cultures, each set consisting of one aerobic and one anaerobic bottle. Cultures were incubated ≤5 days in the BacT/Alert 3D and Bactec FX instruments, respectively. A total of 128 unique BSI episodes were identified based on the recovery of clinically significant growth in 212 aerobic cultures (106 BacT/Alert and 106 Bactec) and 151 anaerobic cultures (82 BacT/Alert and 69 Bactec). The BacT/Alert aerobic medium had higher recovery rates for Gram-positive cocci (P = 0.024), whereas the Bactec aerobic medium was superior for recovery of Gram-negative bacilli (P = 0.006). BacT/Alert anaerobic medium recovery rates exceeded those of the Bactec anaerobic medium for total organisms (P = 0.003), Gram-positive cocci (P = 0.013), and Escherichia coli (P = 0.030). In terms of capacity for diagnosing the 128 septic episodes, the BacT/Alert and Bactec sets were comparable, although the former sets diagnosed more BSIs caused by Gram-positive cocci (P = 0.008). They also allowed earlier identification of coagulase-negative staphylococcal growth (mean, 2.8 h; P = 0.003) and growth in samples from patients not on antimicrobial therapy that yielded positive results (mean, 1.3 h; P < 0.001). Similarly high percentages of microorganisms in BacT/Alert and Bactec cultures (93.8% and 93.3%, respectively) were identified by direct matrix-assisted laser desorption ionization–time of flight mass spectrometry assay of BC broths. The BacT/Alert Plus media line appears to be a reliable, timesaving tool for routine detection of BSIs in the population we studied, although further studies are needed to evaluate their performance in other settings.
机译:我们比较了带有吸附性聚合物珠的BacT / Alert Plus(bioMérieux)和Bactec Plus(Becton Dickinson)有氧和厌氧血培养(BC)培养基的临床表现。 ≥16岁的怀疑有血液感染(BSI)的患者被纳入重症监护病房和传染病病房。从每个收集一个40毫升血液样本,并用于接种(10毫升/瓶)一组BacT / Alert Plus培养物和一组Bactec Plus培养物,每组由一个有氧和一个厌氧瓶组成。将培养物分别在BacT / Alert 3D和Bactec FX仪器中孵育≤5天。根据212个有氧培养物(106 BacT / Alert和106 Bactec)和151个厌氧培养物(82 BacT / Alert和69 Bactec)的临床显着生长的恢复,确定了总共128个独特的BSI发作。 BacT / Alert有氧培养基对革兰氏阳性球菌的回收率更高( P = 0.024),而Bactec有氧培养基对革兰氏阴性杆菌( P > = 0.006)。 BacT / Alert厌氧培养基的回收率超过了Bactec厌氧培养基的总生物量( P = 0.003),革兰氏阳性球菌( P = 0.013)和大肠杆菌( P = 0.030)。就诊断128例败血症的能力而言,BacT / Alert和Bactec组具有可比性,尽管前一组诊断出更多由革兰氏阳性球菌引起的BSI( P = 0.008)。他们还允许较早鉴定凝固酶阴性葡萄球菌的生长(平均2.8 h; P = 0.003)和未接受抗微生物治疗的患者样品中的生长,这些结果产生了阳性结果(平均1.3 h; P <0.001)。同样,通过直接基质辅助激光解吸电离-飞行时间质谱法测定的BC肉汤,在BacT / Alert和Bactec培养物中的微生物百分比也很高(分别为93.8%和93.3%)。 BacT / Alert Plus培养基系列似乎是可靠,省时的工具,可用于常规检测我们所研究人群中的BSI,尽管还需要进一步的研究来评估其在其他环境中的表现。

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号