...
首页> 外文期刊>Journal of Clinical Microbiology >Comparison of sensititre broth microdilution and agar dilution susceptibility testing techniques for meropenem to determine accuracy, reproducibility, and predictive values.
【24h】

Comparison of sensititre broth microdilution and agar dilution susceptibility testing techniques for meropenem to determine accuracy, reproducibility, and predictive values.

机译:美罗培南敏化液微稀释液和琼脂稀释液药敏试验技术的比较,以确定准确性,可重复性和预测值。

获取原文
           

摘要

The stability, accuracy, reproducibility, and predictive value of Sensititre MIC panels containing meropenem (Merrem) were evaluated by using National Committee for Clinical Laboratory Standards (NCCLS)-recommended American Type Culture Collection (ATCC) strains and 110 selected strains of rapidly growing and fastidious aerobes and anaerobes with various degrees of susceptibility to meropenem. The NCCLS-recommended agar dilution method was used as a standard reference method. Meropenem-containing Sensititre MIC panels were monitored for their stabilities at room temperature and reproducibilities over 24 months by using six ATCC strains. Ninety-nine percent of the MICs of both meropenem and imipenem obtained for NCCLS-recommended ATCC strains were within the established ranges after 2 years. The overall agreement (+/- 1 twofold dilution) between the Sensititre and the agar dilution meropenem MICs was greater than 93%. The predictive value of meropenem MICs for indicating suspeptibility or resistance obtained by the Sensititre method was greater than 90%. No major or very major interpretive errors were observed, and only 5% of meropenem MICs were associated with minor interpretive errors. Problematic organisms were not observed. The Sensititre MIC panels containing meropenem offer a convenient and valid alternative to the NCCLS reference method for the susceptibility testing of potential pathogens likely to be recovered from mixed infections.
机译:通过使用美国临床实验室标准委员会(NCCLS)推荐的美国典型培养物保藏中心(ATCC)菌株和110种快速生长和繁殖的菌株,评估了含有美罗培南(Merrem)的Sensititre MIC板的稳定性,准确性,可重复性和预测价值。对美罗培南有不同程度敏感性的挑剔的需氧菌和厌氧菌。 NCCLS推荐的琼脂稀释方法用作标准参考方法。使用六种ATCC菌株监测了含美罗培南的Sensititre MIC板在室温下的稳定性以及在24个月内的再现性。 NCCLS推荐的ATCC菌株获得的美罗培南和亚胺培南的MIC的99%在2年后均处于既定范围内。 Sensititre和琼脂稀释美罗培南MIC的总体一致性(+/- 1倍稀释度)大于93%。美洛培南MICs用于指示通过Sensititre方法获得的易感性或耐药性的预测值大于90%。没有观察到重大或非常重大的解释错误,只有5%的美罗培南MICs与较小的解释错误相关。没有观察到有问题的生物。含有美罗培南的Sensititre MIC面板为NCCLS参考方法提供了一种方便有效的替代方法,用于对可能从混合感染中恢复的潜在病原体进行药敏试验。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号