摘要

Persistent concerns about limitation in the assessment of the quality control of Autobac 1 (Pfizer Diagnostics Division, Groton, Conn.) led us to investigate an alternative method for monitoring the performance of Autobac susceptibility testing disks. Current methodology for quality control of the system provides data which are interpreted at the high end of a numerical scale; e.g., the control strain of Escherichia coli consistently exhibits a light-scattering index value of 1.00 for all antibiotics tested. This type of end-of-scale criterion may not detect individual antibiotic disk aberrations of individual clinical isolate susceptibilities. Disk diffusion testing allows a semiquantitative, continuous-scale determination and will detect test performance variations, unless the control strain is highly resistant. During a 6-month period daily quality control procedures for 10 Autobac antibiotics tested against control strains of E. coli and Pseudomonas aeruginosa were monitored, utilizing both Autobac 1 recommendations and disk diffusion susceptibility (Kirby-Bauer) methodology. Readings were carried out by one of six technologists. Zone sizes were within a range of +/- 3 mm of a mean value of 99% of the tests with E. coli and within +/- 3 mm for 98% of the tests with Pseudomonas. Reproducibility was excellent. The high reproducibility may be due to the disk manufacturing process, which provides rigorous disk preparation and acceptability standards, to strict laboratory storage procedure, and to our own careful assessment of disk cartridges before their use for clinical susceptibility testing. We recommend that each new cartridge be tested in this manner and that a similar procedure be considered for other automated procedures in which disks are used.
机译:由于对Autobac 1的质量控制评估存在局限性(Pfizer Diagnostics Division,Gronton,康涅狄格州)的持续关注,导致我们研究了一种监测Autobac磁化率测试磁盘性能的替代方法。当前的系统质量控制方法论提供的数据在数字量级的高端得以解释;例如,对于所有测试的抗生素,大肠杆菌的对照菌株始终显示出1.00的光散射指数值。这种类型的规模终极标准可能无法检测到各个临床分离物敏感性的单个抗生素盘异常。圆盘扩散测试允许半定量,连续规模的确定,并且将检测测试性能变化,除非控制应变具有很高的抵抗力。在6个月内,利用Autobac 1建议和磁盘扩散敏感性(Kirby-Bauer)方法,对针对大肠杆菌和铜绿假单胞菌的对照菌株测试的10种Autobac抗生素的日常质量控制程序进行了监测。阅读是由六位技术人员之一进行的。区域大小在大肠杆菌的99%测试平均值的+/- 3 mm范围内,对于假单胞菌98%的测试平均值在+/- 3 mm范围内。重现性极好。高可重复性可能是由于磁盘制造过程提供了严格的磁盘准备和可接受性标准,严格的实验室存储程序以及我们自己对磁盘盒进行临床敏感性测试之前的仔细评估。我们建议以这种方式测试每个新盒式磁带,并且对于使用磁盘的其他自动过程,也应考虑类似的过程。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号