Both the standard mercury sphygmomanometer and the random-zero sphygmomanometer have been used in epidemiological studies and clinical trials. Problems arise in comparing studies since, in addition to other methodological differences, the readings obtained with the random-zero sphygmomanometer have been found to be lower than those obtained with the standard mercury sphygmomanometer. In the present study, blood pressures were measured in 66 subjects to examine the comparability of findings with the two instruments. Trained observers measured blood pressures simultaneously using a double-headed stethoscope and one cuff connected to the two sphygmomanometers. Use of instrument was randomly assigned for each blood pressure measurement; each observer was unaware of the other's blood pressure reading. Readings were lower with the random-zero sphygmomanometer; mean difference ranged from 2.5 to 3.3 mm Hg for systolic pressure and 1.9 to 2.7 mm Hg for diastolic pressure. Digit distributions recorded by the two observers for the standard mercury sphygmomanometer and the random-zero sphygmomanometer were not significantly different for either systolic or diastolic blood pressure. Intraindividual variation was greater with the random-zero sphygmomanometer than with the standard mercury sphygmomanometer. These data do not indicate that one instrument is clearly superior to the other, although in studies where the observer seeks to reduce the bias of multiple readings per person, the random-zero sphygmomanometer may be the more appropriate instrument. Critical to the use of either instrument are careful training, standardization, certification, and periodic recertification of observers.
机译:标准的汞血压计和随机零血压计均已在流行病学研究和临床试验中使用。在比较研究中会出现问题,因为除其他方法上的差异外,发现随机零血压计所获得的读数要低于标准汞血压计所获得的读数。在本研究中,对66位受试者的血压进行了测量,以检查这两种仪器的发现是否具有可比性。受过训练的观察者使用双头听诊器和连接到两个血压计的一个袖带同时测量血压。每次血压测量均随机分配使用仪器。每个观察者都不知道对方的血压读数。随机零血压计的读数较低。平均压差范围为收缩压2.5至3.3 mm Hg和舒张压1.9至2.7 mm Hg。两位观察者记录的标准水银血压计和随机零血压计的数字分布对于收缩压或舒张压均无显着差异。零血压血压计的个人差异大于标准汞血压计。这些数据并未表明一种仪器明显优于另一种仪器,尽管在研究中观察者试图降低每人多次读数的偏差,但零血压血压计可能是更合适的仪器。使用这两种仪器的关键是对观察者进行仔细的培训,标准化,认证和定期重新认证。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号