首页> 外文期刊>The Journal of Bone and Joint Surgery. British VolumecBritish Orthopaedic Association , Australian Orthopaedic Association , Canadian Orthopaedic Association . . . [et al] >Focal femoral osteolysis after revision hip replacement with a cannulated, hydroxyapatite-coated long-stemmed femoral component
【24h】

Focal femoral osteolysis after revision hip replacement with a cannulated, hydroxyapatite-coated long-stemmed femoral component

机译:用空心羟基磷灰石涂层的长柄股骨假体置换髋关节置换后的股骨股骨溶解

获取原文
           

摘要

We describe a case of symptomatic focal femoral osteolysis around a screw hole distal to the hydroxyapatite-coated portion of a cannulated femoral component in a revision hip replacement. No locking screw had been inserted into this, the most proximal of the three distal holes for locking screws. The presence of polyethylene wear debris in the tissue excised from the lesion suggested that it had passed through the cannulated portion of the stem and out of the proximal unfilled distal locking hole, initiating an osteolytic reaction in an otherwise well-fixed stem. This case highlights an important design characteristic of such cannulated, uncemented femoral components. We recommend that the proximal aperture of these cannulated stems be occluded at implantation.
机译:我们描述了在髋关节翻修术中股骨头假体的羟基磷灰石涂层部分远端的螺丝孔周围出现症状性局灶性股骨骨溶解的情况。没有将锁定螺钉插入其中,这是三个用于锁定螺钉的远端孔中最靠近的孔。从病变处切除的组织中存在聚乙烯磨损碎片,这表明聚乙烯磨损碎片已经穿过茎的插管部分,并从近端未充满的远端锁定孔中逸出,从而在原本固定良好的茎中引发了溶骨反应。这种情况突出了这种插管的,非骨水泥化的股骨组件的重要设计特征。我们建议在植入时将这些空心茎的近端孔闭塞。
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号