首页> 外文期刊>The Journal of Bone and Joint Surgery. British VolumecBritish Orthopaedic Association , Australian Orthopaedic Association , Canadian Orthopaedic Association . . . [et al] >The effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic review
【24h】

The effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic review

机译:改进的固井技术对全髋关节置换中的成分松弛的影响。长达11年的放射线检查

获取原文
       

摘要

Improved cementing techniques have been shown to decrease the rate of aseptic loosening of femoral components of cemented total hip replacements at five to seven years. We now report our results in 105 hips in 93 patients at 10 to 12.7 years (mean 11.2). The improved techniques included use of a medullary plug, a cement gun, a doughy mix of Simplex P and a collared stem of chrome cobalt. Only three femoral components had definitely loosened, none were probably loose and 24 were graded as possibly loose. In contrast, the incidence of radiographic loosening on the acetabular side was 42%. Improved cementing techniques have produced a marked reduction in the rate of aseptic loosening of the femoral component, but the incidence of acetabular loosening is unchanged.
机译:研究表明,改进的胶结技术可在五到七年内降低全髋置换术的股骨组件无菌性松动的速度。现在,我们报告了93位10至12.7岁患者的105髋的研究结果(平均11.2)。改进的技术包括使用髓塞,水泥枪,Simplex P的面团状混合物和铬钴的颈状茎。只有三个股骨组件确实松动,没有一个可能松动,有24个被分级为可能松动。相反,髋臼侧放射学松动的发生率为42%。改良的固井技术已使股骨组件的无菌松动率显着降低,但髋臼松动的发生率未改变。
获取原文