An investigation into contamination of operative suction

机译:手术吸痰污染调查

获取原文
           

摘要

A study of the contamination of suckers used during total hip replacement has been undertaken. Thirty suckers used throughout the operation had their tips cultured: from 11 of these bacteria were grown. The organisms found were those which have previously been implicated in deep infection of total hip replacements. In subsequent operations a further 31 suckers were used for cleaning only the femoral shaft; of these only one was contaminated. This suggests that sucker contamination is related to how long the sucker is in use; consequently it is recommended that a new sucker be used for the preparation of the femoral shaft.
机译:已经对全髋关节置换术期间使用的抽油机的污染进行了研究。整个手术过程中使用了30个吸盘,培养了吸头:这些细菌中有11种已经生长。所发现的生物是那些先前与全髋关节置换术的深层感染有关的生物。在随后的手术中,另外31个吸盘仅用于清洁股骨干。其中只有一个被污染了。这表明吸盘的污染与吸盘的使用时间有关。因此,建议使用新的吸盘准备股骨干。