首页> 外文期刊>Sensors >Determination of Zinc, Cadmium, Lead, Copper and Silver Using a Carbon Paste Electrode and a Screen Printed Electrode Modified with Chromium(III) Oxide
【24h】

Determination of Zinc, Cadmium, Lead, Copper and Silver Using a Carbon Paste Electrode and a Screen Printed Electrode Modified with Chromium(III) Oxide

机译:碳糊电极和氧化铬(III)修饰的丝网印刷电极测定锌,镉,铅,铜和银

获取原文
           

摘要

In this study, the preparation and electrochemical application of a chromium(III) oxide modified carbon paste electrode (Cr-CPE) and a screen printed electrode (SPE), made from the same material and optimized for the simple, cheap and sensitive simultaneous determination of zinc, cadmium, lead, copper and the detection of silver ions, is described. The limits of detection and quantification were 25 and 80 μg·L ?1 for Zn(II), 3 and 10 μg·L ?1 for Cd(II), 3 and 10 μg·L ?1 for Pb(II), 3 and 10 μg·L ?1 for Cu(II), and 3 and 10 μg·L ?1 for Ag(I), respectively. Furthermore, this promising modification was transferred to the screen-printed electrode. The limits of detection for the simultaneous determination of zinc, cadmium, copper and lead on the screen printed electrodes were found to be 350 μg·L ?1 for Zn(II), 25 μg·L ?1 for Cd(II), 3 μg·L ?1 for Pb(II) and 3 μg·L ?1 for Cu(II). Practical usability for the simultaneous detection of these heavy metal ions by the Cr-CPE was also demonstrated in the analyses of wastewaters.
机译:在这项研究中,氧化铬(III)修饰的碳糊电极(Cr-CPE)和丝网印刷电极(SPE)的制备和电化学应用由相同的材料制成,并经过优化,可同时进行简单,廉价和灵敏的测定描述了锌,镉,铅,铜的检测以及银离子的检测。 Zn(II)的检出限和定量限分别为25和80μg·L?1,Cd(II)的检出限为3和10μg·L?1,Pb(II)的检出限为3和10μg·L?1对于Cu(II)为10μg·L≤1,对于Ag(I)为10μg·L≤1。此外,这种有希望的修饰被转移到丝网印刷电极上。同时测定丝网印刷电极上锌,镉,铜和铅的检测限为Zn(II)为350μg·L?1,Cd(II)为25μg·L?1,3对于Pb(II)为μg·L?1,对于Cu(II)为3μg·L?1。在废水分析中还证明了通过Cr-CPE同时检测这些重金属离子的实用性。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号