首页> 外文期刊>Sensors >Determination of Trace Antimony (III) by Adsorption Voltammetry at Carbon Paste Electrode
【24h】

Determination of Trace Antimony (III) by Adsorption Voltammetry at Carbon Paste Electrode

机译:碳糊电极上吸附伏安法测定痕量锑(Ⅲ)

获取原文
           

摘要

This work presents a sensitive method for the determination of trace antimony based on the antimony-pyrogallol red (PGR) adsorption at a carbon paste electrode (CPE). The optimal conditions were to use an electrode containing 25% paraffin oil and 75% high purity graphite powder as working electrode, a 0.10 mol/L HCl solution containing 3.0×10-5 mol/L PGR as accumulation medium and a 0.20 mol/L HCl solution as electrolyte with an accumulation time of 150 s and a reduction time of 60 s at -0.50 V followed with a sweep from -0.50 V to 0.20 V. The mechanism of the electrode reaction was discussed. Interferences of other metal ions were studied as well. The detection limit was 1×10-9 mol/L. The linear range was from 2.0×10-9 mol/L to 5.0×10-7 mol/L. Application of the proposed method to the determination of antimony in water and human hair samples gave good results.
机译:这项工作提出了一种基于碳糊电极(CPE)上的锑-间苯三酚红(PGR)吸附测定痕量锑的灵敏方法。最佳条件是使用含25%石蜡油和75%高纯度石墨粉的电极作为工作电极,并使用0.10 mol / L HCl溶液(累积量为3.0×10 -5 mol / L PGR)作为电极。介质和0.20 mol / L HCl溶液作为电解质,在-0.50 V时的累积时间为150 s,还原时间为60 s,然后从-0.50 V扫描至0.20V。讨论了电极反应的机理。还研究了其他金属离子的干扰。检出限为1×10 -9 mol / L。线性范围为2.0×10 -9 mol / L至5.0×10 -7 mol / L。将该方法用于水和人发样品中锑的测定,结果良好。