摘要

Foodborne pathogens are of significant concern in the agrifood industry and the development of associated rapid detection and identification methods are of major importance. This paper describes the novel use of resolution-optimized prism-based surface plasmon resonance imaging (RO-SPRI) and data processing for the detection of the foodborne pathogens Listeria monocytogenes and Listeria innocua . With an imaging spatial resolution on the order of individual bacteria (2.7 ± 0.5 μm × 7.9 ± 0.6 μm) over a field of view 1.5 mm ~(2) , the RO-SPRI system enabled accurate counting of individual bacteria on the sensor surface. Using this system, we demonstrate the detection of two species of Listeria at an initial concentration of 2 × 10 ~(2) CFU mL ~(?1) in less than 7 hours. The surface density of bacteria at the point of positive detection was 15 ± 4 bacteria per mm ~(2) . Our approach offers great potential for the development of fast specific detection systems based on affinity monitoring.
机译:食源性病原体是农业食品行业中的重要问题,相关快速检测和鉴定方法的发展至关重要。本文介绍了基于分辨率优化的基于棱镜的表面等离振子共振成像(RO-SPRI)和数据处理在食源性单核细胞增生李斯特菌和无毒李斯特菌检测中的新颖用途。通过在1.5 mm〜(2)的视场上以单个细菌的数量级(2.7±0.5μm×7.9±0.6μm)的成像空间分辨率,RO-SPRI系统可以准确计数传感器表面上的单个细菌。使用该系统,我们证明了在不到7小时的时间内检测到两种浓度为2×10〜(2)CFU mL〜(?1)的李斯特菌。阳性检测点的细菌表面密度为15±4细菌/ mm〜(2)。我们的方法为开发基于亲和力监测的快速特异性检测系统提供了巨大的潜力。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号