In normative documents for definition of time of approach of critical values of dangerous factors of the fire (DFF) use medium-volume characteristics of temperature, concentration of O_(2)oxygen, toxiferous gases and smoke. The purpose of this work – to show that for calculating time of approach of dangerous factors of the fire it is necessary to consider the place of the expiration of gases and their initial parameters. The expressions received in work can serve for determination of values of the dangerous factors of the fire parameters indoors depending on time, taking into account the place of the expiration of gases and their initial parameters. From the dependences given in work it is visible that differences in time taking into account the place of the expiration for the room of 5000 m~(3)are made by not less than 30 c with on reaching critical temperature and critical concentration of O_(2). Especially it should be noted that at change of height of a working zone the time difference increases to 40 c with in both parameters.
机译:在用于定义火灾危险因素(DFF)临界值接近时间的规范性文件中,使用中等体积的温度,O_(2)氧气浓度,有毒气体和烟雾的特征。这项工作的目的–表明为了计算接近火灾危险因素的时间,有必要考虑气体过期的位置及其初始参数。在工作中收到的表达式可用于根据时间确定室内火灾参数的危险因素的值,同时考虑到气体的到期地点及其初始参数。从工作中给出的依赖关系可以看出,考虑到5000 m〜(3)房间的到期时间,在达到临界温度和O_(临界浓度)时,时间差不少于30 c。 2)。特别要注意的是,在工作区高度变化时,两个参数的时间差都增加到40 c。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号