Results of research of influence of radiation heat exchange on duration of execution of measurement high темератур are given by thermocouples, influence of the free convection on results of temperature measurement is also considered by the thermocouples set in protective sleeves with a gap. Researches showed that radiation heat exchange leads to lowering of duration of heating of the thermocouple to 30% whereas the free convection in a protective sleeve practically doesn’t exert impact on process of heating up of the sensor.
机译:热电偶给出了辐射热交换对高测量执行时间的影响的研究结果,自由对流对温度测量结果的影响也被设置在有间隙的保护套中的热电偶考虑。研究表明,辐射热交换可将热电偶的加热时间降低到30%,而保护套中的自由对流实际上不会对传感器的加热过程产生影响。