首页> 外文期刊>E3S Web of Conferences >Performance of a Retrofitted Multicyclone for PM 2.5 Emission Control
【24h】

Performance of a Retrofitted Multicyclone for PM 2.5 Emission Control

机译:改进型多旋风除尘器 2.5 的排放控制性能

获取原文
           

摘要

This paper presents on the performance of a retrofitted multicyclone system, which aims to increase the collection efficiency of PM_(2.5)(i.e. particulate size fraction ≤ 2.5 μm) emission. The multicyclone was retrofitted by extracting 15% and 20% of the total volumetric air flow rate at the dust hopper of the unit using an additional Induced Draft Fan. The total collection efficiency with and without the extraction was measured at various air volumetric flow rates and particulate mass inlet concentration. The results showed that there was a reduction of 12% to 54% depending on the inlet concentration of PM2.5 emission in the stack with compared to without extraction increasing the collection efficiency of the retrofitted multicyclone. The finding suggests that a simple technique of applying gas extraction at the dust hopper of a multicyclone as reported in this study able to increase the overall performance in fine particulate collection.
机译:本文介绍了一种改进的多旋风系统的性能,该系统旨在提高PM_(2.5)(即颗粒尺寸分数≤2.5μm)排放物的收集效率。通过使用额外的引风机将单元的集尘斗中总风量的15%和20%抽出,对多旋风器进行了改造。在各种空气体积流量和颗粒物质入口浓度下,测量有无萃取的总收集效率。结果表明,与不抽气相比,取决于烟囱中PM2.5排放的入口浓度,减少了12%至54%,从而提高了改装后的多旋风分离器的收集效率。该发现表明,如本研究中所报道的,在多旋风除尘器的灰斗上进行抽气的简单技术能够提高细颗粒收集的整体性能。