Concrete filled hollow steel section column have been widely accepted by structural engineers and designers for high rise construction due to the benefits of combining steel and concrete. The advantages of concrete filled hollow steel section column include higher strength, ductility, energy absorption capacity, and good structural fire resistance. In this paper, comparison on the fire performance between circular and square concrete filled hollow steel section column is established. A three-dimensional finite element package, ABAQUS, was used to develop the numerical model to study the temperature development, critical temperature, and fire resistance time of the selected composite columns. Based on the analysis and comparison of typical parameters, the effect of equal cross-sectional size for both steel and concrete, concrete types, and thickness of external protection on temperature distribution and structural fire behaviour of the columns are discussed. The result showed that concrete filled hollow steel section column with circular cross-section generally has higher fire resistance than the square section.
机译:由于钢和混凝土结合的优点,空心混凝土型钢填充柱已被结构工程师和设计师广泛接受用于高层建筑。空心混凝土截面型钢的优点包括更高的强度,延展性,能量吸收能力以及良好的结构耐火性。本文建立了圆形和方形空心混凝土截面型钢的耐火性能的比较。使用三维有限元程序包ABAQUS来开发数值模型,以研究所选复合柱的温度变化,临界温度和耐火时间。在对典型参数进行分析和比较的基础上,讨论了钢和混凝土等截面尺寸,混凝土类型以及外部保护层厚度对柱温度分布和结构火灾行为的影响。结果表明,圆形截面的空心混凝土截面混凝土柱的耐火性通常比方形截面高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号