The nuclear radiation energy deposition rate is a key value for the thermal design of experiments, on materials and nuclear fuels, carried out in experimental channels of nuclear research reactors. Studies are led for two kinds of sensor currently dedicated to quantifying this value and corresponding to calorimeter. Development of new sensors but also improvement of their calibration and their associated interpretation methods are necessary. These aims are possible by many ways such as numerical simulations of sensor, characterizations under laboratory conditions and experimental campaign under irradiation conditions. The calibration step under non-irradiation conditions represents a crucial phase. This phase requires the development of specific benches. The present paper focuses on a new thermal-transient bench and its use to perform calibration of a polish single-cell calorimeter. The new bench is detailed. First studies of the influence of external conditions (temperature, velocity) on the calorimeter sensitivity are presented and discussed.
机译:核辐射能沉积速率是在核研究反应堆实验通道中进行的材料和核燃料实验热设计的关键值。针对目前专用于量化该值并对应于热量计的两种传感器进行了研究。必须开发新的传感器,而且还需要改进其校准及其相关的解释方法。这些目标可以通过多种方式实现,例如传感器的数值模拟,实验室条件下的表征以及辐射条件下的实验活动。在非辐照条件下的校准步骤代表了一个关键阶段。此阶段需要开发特定的基准。本文着重介绍了一种新型的热瞬态工作台及其在抛光单细胞量热仪的校准中的应用。新的工作台已详细说明。提出并讨论了外部条件(温度,速度)对热量计灵敏度的影响的初步研究。