The guidelines for the design of rural and urban power supply systems do not consider the issues of reactive power compensation and reduction in additional losses due to unbalanced and non-sinusoidal conditions. At the same time, today’s rural power consumers have a great number of non-linear loads in their residential premises. Moreover, the unbalanced phase currents and voltages are an established fact. The paper aims to demonstrate the extent to which power quality and losses vary in real rural 0.38 kV networks. To this end, the objectives were posed to study the operation of two facilities: 1- switchgear at the cottage (with an installed capacity of 15 kW); 2- switchgear at the communal entrance hallway for 60 apartments in an apartment building (with an installed capacity of 75 kW).
机译:农村和城市供电系统的设计指南没有考虑无功补偿和由于不平衡和非正弦条件而导致的额外损失减少的问题。同时,当今的农村用电用户在其住宅场所中承受着大量的非线性负荷。而且,不平衡的相电流和电压是已经确定的事实。本文旨在证明在实际的农村0.38 kV网络中电能质量和损耗的变化程度。为此,提出了研究两个设施运行的目标:1-小屋的开关设备(装机容量为15 kW); 2 –在一栋公寓楼中60套公寓的公共入口走廊的开关柜(装机容量为75 kW)。