?Purpose?To characterize inter-clinician (IC) variability in assigning disc margin and rim margin within 184 color stereophotos of glaucoma and glaucoma suspect eyes.?Methods?Photos of 184 eyes of 184 subjects were independently evaluated by 5 trained glaucoma specialists. Stereophoto pairs were viewed using a handheld stereoscope while the disc margin and rim margin were marked using a separate monitor and customized software. For each photo, the centroid of each clinician’s disc margin was calculated, and an average DMcentroid (n=5 clinicians) was determined. Photos were then colocalized to confocal scanning laser ophthalmoscopy (cSLO) infrared fundus reflectance images of the same eye so that the axis between DMcentroid and the fovea could be used to establish anatomic 30-degree sectors in each eye. (Fig 1) Radial distance measurements from DMcentroid to each clinician’s disc margin (disc radius) and rim margin (cup radius) were noted and used to calculate the rim width, disc area, cup area and rim area in each sector. IC variability for each parameter (disc radius, cup radius, rim width, disc area, cup area and rim area) within the 184 photos was assessed as the standard deviation of differences from the intra-eye inter-clinician mean within each sector.?Results?IC variability for each parameter was substantial and regionally variable in these 184 eyes. Among the distance parameters, cup radius was more variable than disc radius in all 12 sectors with each being greatest nasally (see Fig 2 for polar plots of the SD of residuals for all parameters). Cup area was more variable than disc area superotemporally but less variable inferonasally due to the reduced extent of the cup in the inferonasal region. Variability in rim width comprises the effect of variability on both rim margin and disc margin, so is greater than either. Similarly rim area is more variable than either cup area or disc area since it incorporates both sources of variability.?Conclusions?IC variability in rim margin and disc margin assessment was substantial among the glaucoma specialists of this study leading to marked IC variability in rim width and rim area assessment. Reducing variance due to a well known source of anatomical variation is beneficial. A regionalization strategy based on the angle between the disc center and fovea is a useful approach for standardizing optic disc assessment by sectors. ?View OriginalDownload Slide?Figure 1?Figure 1View OriginalDownload Slide?View OriginalDownload Slide?Figure 2?Figure 2View OriginalDownload Slide? Keywords: 627 optic disc ? 629 optic nerve ? 610 nerve fiber layer ?.
机译:目的:表征184位青光眼和可疑青光眼彩色立体照片中的椎间盘边缘和边缘边缘的临床差异(IC)。方法:由5位受过训练的青光眼专家对184位受试者的184只眼睛的照片进行独立评估。使用手持式立体镜观看立体照片对,同时使用单独的监视器和定制软件标记光盘边缘和边缘边缘。对于每张照片,计算每个临床医生的椎间盘边缘的质心,并确定平均DM质心(n = 5个临床医生)。然后将照片共定位到同一只眼睛的共聚焦扫描激光检眼镜(cSLO)红外眼底反射图像,以便DMcentroid和中央凹之间的轴可用于在每只眼睛中建立30度解剖区域。 (图1)记录了从DMcentroid到每个临床医生的椎间盘边缘(光盘半径)和边缘边缘(杯半径)的径向距离测量值,并用于计算每个扇区的边缘宽度,圆盘面积,杯面积和边缘面积。将184张照片中每个参数(光盘半径,杯半径,边缘宽度,圆盘面积,杯面积和边缘面积)的IC变异性评估为与每个扇区内眼内临床医生平均数的差异的标准偏差。结果在这184只眼中,每个参数的IC差异均很大,且存在区域差异。在距离参数中,杯半径在所有12个扇区中都比圆盘半径变化更大,每个扇区的鼻部最大(所有参数的残差SD的极坐标图见图2)。杯面积在颞上比椎间盘面积变化更大,但由于在鼻下区域中杯的减小,因此在鼻下变化较小。轮辋宽度的可变性包括可变性对轮辋边缘和圆盘边缘的影响,因此大于两者之一。同样,边缘区域比杯状区域或椎间盘区域的可变性都大,因为它同时包含了两个可变性来源。和边缘区域评估。减少由于众所周知的解剖学变化源而引起的变化是有益的。基于光盘中心和中央凹之间的角度的区域化策略对于标准化按扇区进行的光盘评估是一种有用的方法。查看原始下载幻灯片图1图1查看原始下载幻灯片查看原始下载幻灯片图2图2查看原始下载幻灯片关键字:627光盘629视神经? 610神经纤维层。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号