首页> 外文期刊>International Journal of Engineering Research and Applications >Improved Active Power Filter Performance for Renewable Power Generation Systems
【24h】

Improved Active Power Filter Performance for Renewable Power Generation Systems

机译:改进了可再生能源发电系统的有源电力滤波器性能

获取原文
           

摘要

An active power filter implemented with a four-leg voltage-source inverter using a predictive control scheme is presented. Traditionally, active power filters have been controlled using pretuned controllers, such as PI-type or adaptive, for the current as well as for the dc-voltage loops. PI controllers must be designed based on the equivalent linear model, while predictive controllers use the nonlinear model, which is closer to real operating conditions. An accurate model obtained using predictive controllers improves the performance of the active power filter, especially during transient operating conditions, because it can quickly follow the current-reference signal while maintaining a constant dc-voltage. Although active power filters implemented with three-phase four-leg voltage-source inverters are presented in this paper. The use of a four-leg voltagesource inverter allows the compensation of current harmonic components, as well as unbalanced current generated by single-phase.....
机译:提出了一种采用预测控制方案的四脚电压源逆变器实现的有源功率滤波器。传统上,有源功率滤波器是使用预调谐控制器(例如PI型或自适应控制器)针对电流以及直流电压环路进行控制的。 PI控制器必须基于等效线性模型进行设计,而预测控制器则使用更接近实际运行条件的非线性模型。使用预测控制器获得的准确模型可以改善有源功率滤波器的性能,尤其是在瞬态工作条件期间,因为它可以快速跟踪电流参考信号,同时保持恒定的直流电压。尽管本文介绍了采用三相四脚电压源逆变器实现的有源功率滤波器。使用四脚电压源逆变器可以补偿电流谐波分量以及单相产生的不平衡电流。