In this paper, the operation principle of the Z-source inverter is analysed in detail. According to the characteristics of allowed short¨C shrougt zero state in the Z-source inverter, SPWM control method of the Z-source inverter is obtained by inserting fixed short¨Cshrougt zero state into zero state of SPWM. It is simple and easily implemented in practice. However, in inductive load condition the output voltage and current of Z-source inverter have serious distortion and affect the inverting quality. The cause of this distortion is analysed in detail and an improved SPWM control method is proposed, which can better solve the output voltage and current distortion problem of the Z-source inverter under the condition of inductive load. Matlab simulation results verify that the improved SPWM control method not only eliminates distortion caused by inductive load, but also decreases the switch times and quantities in each cycle. Therefore, it decreases the THD of AC output effectively and improves the efficiency of the inverter, and its theoretical analysis is verified to be effective
机译:本文详细分析了Z源逆变器的工作原理。根据Z源逆变器允许短路短路保护零状态的特点,通过将固定短路短路保护零状态插入SPWM的零状态,得到Z源逆变器的SPWM控制方法。它很简单,在实践中很容易实现。但是,在感性负载条件下,Z源逆变器的输出电压和电流会严重失真,并影响逆变质量。详细分析了这种畸变的原因,并提出了一种改进的SPWM控制方法,可以更好地解决电感性负载条件下Z源逆变器的输出电压和电流畸变问题。 Matlab仿真结果证明,改进的SPWM控制方法不仅消除了感性负载引起的失真,而且减少了每个周期的开关次数和数量。因此,它有效地降低了交流输出的总谐波失真,提高了逆变器的效率,其理论分析被证明是有效的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号