首页> 外文期刊>Applied Microbiology >Selection of a Microbiological Corrosion System for Studying Effects on Structural Aluminum Alloys
【24h】

Selection of a Microbiological Corrosion System for Studying Effects on Structural Aluminum Alloys

机译:用于研究对结构铝合金的影响的微生物腐蚀系统的选择

获取原文
           

摘要

Two laboratory methods, a metal-strip test and a tank test, were evaluated as microbiological corrosion systems for producing corroded test specimens on a structural aluminum alloy. The results show that corrosion of the test alloy occurred best in the metal-strip test in a deionized water-fuel medium inoculated with a mixture of microorganisms under aerated conditions. The metal-strip test was more successful for producing large numbers of corroded test specimens and proved more economical than the tank-type test, since less structural material is needed to obtain a specimen with sufficient corrosion areas, and since the corrosion can more easily be restricted by maskants to certain areas for specific test purposes.
机译:作为微生物腐蚀系统,对两种实验室方法(金属条测试和储罐测试)进行了评估,以用于在结构铝合金上生产被腐蚀的试样。结果表明,在曝气条件下接种微生物混合物的去离子水-燃料介质中,金属带测试中,测试合金的腐蚀效果最佳。金属带测试对于生产大量腐蚀的试样更成功,并且比罐式测试更经济,因为获得具有足够腐蚀面积的试样所需的结构材料更少,而且腐蚀更容易为了特定的测试目的,被掩蔽剂限制在某些区域。