首页> 外文期刊>Applied and Environmental Microbiology >Evaluation of three portable samplers for monitoring airborne fungi.
【24h】

Evaluation of three portable samplers for monitoring airborne fungi.

机译:评估了三个便携式采样器,用于监测空气中的真菌。

获取原文

摘要

Airborne fungi were monitored at five sample sites with the Burkard portable, the RCS Plus, and the SAS Super 90 air samplers; the Andersen 2-stage impactor was used for comparison. All samplers were calibrated before being used simultaneously to collect 100-liter samples at each site. The Andersen and Burkard samplers retrieved equivalent volumes of airborne fungi; the SAS Super 90 and RCS Plus measurements did not differ from each other but were significantly lower than those obtained with the Andersen or Burkard samplers. Total fungal counts correlated linearly with Cladosporium and Penicillium counts. Alternaria species, although present at all sites, did not correlate with total count or with amounts of any other fungal genera. Sampler and location significantly influenced fungal counts, but no interactions between samplers and locations were found.
机译:使用Burkard便携式,RCS Plus和SAS Super 90空气采样器在五个采样点对空气传播真菌进行了监测;使用Andersen 2级撞击器进行比较。所有采样器均已校准,然后才能在每个站点同时使用以收集100升样品。安德森(Andersen)和伯卡德(Burkard)的采样员回收了等量的空气传播真菌; SAS Super 90和RCS Plus的测量值没有什么不同,但是明显低于使用Andersen或Burkard采样器获得的测量值。总真菌数与枝孢菌和青霉菌数线性相关。链格孢属菌虽然存在于所有部位,但与总计数或任何其他真菌属的数量均不相关。采样器和位置显着影响真菌计数,但未发现采样器和位置之间的相互作用。