A technique for the simultaneous determination of [35S]sulfide and [14C]carbon dioxide produced in anaerobic aqueous samples dual-labeled with [35S]sulfate and a 14C-organic substrate is described. The method involves the passive distillation of sulfide and carbon dioxide from an acidified water sample and their subsequent separation by selective chemical absorption. The recovery of sulfide was 93% for amounts ranging from 0.35 to 50 μmol; recovery of carbon dioxide was 99% in amounts up to 20 μmol. Within these delineated ranges of total sulfide and carbon dioxide, 1 nmol of [35S]sulfide and 7.5 nmol of [14C]carbon dioxide were separated and quantified. Correction factors were formulated for low levels of radioisotopic cross-contamination by sulfide, carbon dioxide, and volatile organic acids. The overall standard error of the method was ±4% for sulfide and ±6% for carbon dioxide.
机译:描述了一种同时测定由[35S]硫酸盐和14C有机底物双重标记的厌氧水性样品中产生的[35S]硫化物和[14C]二氧化碳的技术。该方法包括从酸化水样品中被动蒸馏硫化物和二氧化碳,然后通过选择性化学吸收将其分离。硫化物的回收率为93%,范围为0.35至50μmol。二氧化碳的回收率高达20μmol,为99%。在所描绘的总硫化物和二氧化碳的范围内,分离并定量了1纳摩尔[35S]硫化物和7.5纳摩尔[14C]二氧化碳。针对硫化物,二氧化碳和挥发性有机酸的低水平放射性同位素交叉污染制定了校正因子。该方法的总标准误差对于硫化物为±4%,对于二氧化碳为±6%。