Over the last 5 years, several immunoassay methods for the measurement of B-type natriuretic peptide (BNP) and N-terminal proBNP (NT-proBNP) became commercially available. Recent studies have confirmed the clinical usefulness of measurements of these cardiac natriuretic peptides for the prognostic stratification of patients with congestive heart failure, for the detection of left ventricular systolic and/or diastolic dysfunction, and for the differential diagnosis of dyspnea (1)(2)(3)(4). However, to answer the most urgent requests of current clinical practice and to allow widespread use of BNP and NT-proBNP assays, some key issues had to be solved, such as increasing the sensitivity, precision, and experimental practicability (5). The aim of the present study was to evaluate and compare the analytical and clinical performance of five commercial natriuretic peptide immunoassays.Throughout this report, the values in healthy individuals and patients are reported as the range, median, and 25th and 75th percentiles. We enrolled 172 healthy adults (89 women and 83 men; age range, 16–73 years; median age, 49.0 years; 25th percentile, 38 years; 75th percentile, 58 years). All participants were nonobese (body mass index, 19.4–27.6 kg/m2, 24 kg/m2, 22.8 kg/m2, and 25.6 kg/m2), normotensive (diastolic blood pressure, 60–85 mmHg, 70 mmHg, 70 mmHg, and 80 mmHg; systolic blood pressure, 90–140 mmHg, 120 mmHg, 102.5 mmHg, and 124.5 mmHg), and free from acute or chronic diseases. All participants had main plasma indices (including creatinine, urea nitrogen, glucose, uric acid, albumin, enzymes, electrolytes, and hemoglobin) within the appropriate reference intervals, and normal erythrocyte and leukocyte counts …
机译:在过去的5年中,用于测量B型利钠肽(BNP)和N端proBNP(NT-proBNP)的几种免疫测定方法已商业化。最近的研究证实了测量这些心脏利钠肽对充血性心力衰竭患者的预后分层,检测左心室收缩和/或舒张功能障碍以及鉴别诊断呼吸困难的临床有用性(1)(2) )(3)(4)。然而,为了满足当前临床实践中最紧迫的要求并允许BNP和NT-proBNP测定法的广泛使用,必须解决一些关键问题,例如提高灵敏度,精度和实验实用性(5)。本研究的目的是评估和比较五种市售利尿钠肽免疫测定的分析和临床性能。在本报告中,报告的健康个体和患者的值分别为范围,中位数,第25和第75个百分位数。我们招募了172位健康的成年人(89位女性和83位男性;年龄范围为16-73岁;中位年龄为49.0岁; 25%为38岁; 75%为58岁)。所有参与者均为非肥胖(体重指数:19.4-27.6 kg / m2、24 kg / m2、22.8 kg / m2和25.6 kg / m2),血压正常(舒张压,60-85 mmHg,70 mmHg,70 mmHg,和80 mmHg;收缩压为90-140 mmHg,120 mmHg,102.5 mmHg和124.5 mmHg),且无急性或慢性疾病。在适当的参考间隔内,所有参与者的主要血浆指标(包括肌酐,尿素氮,葡萄糖,尿酸,白蛋白,酶,电解质和血红蛋白)以及正常的红细胞和白细胞计数……

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号