首页> 外文期刊>Clinical Chemistry: Journal of the American Association for Clinical Chemists >Commutability Assessment of Potential Reference Materials Using a Multicenter Split-Patient-Sample Between-Field-Methods (Twin-Study) Design: Study within the Framework of the Dutch Project “Calibration 2000”
【24h】

Commutability Assessment of Potential Reference Materials Using a Multicenter Split-Patient-Sample Between-Field-Methods (Twin-Study) Design: Study within the Framework of the Dutch Project “Calibration 2000”

机译:使用多中心分割患者样本场间方法(孪生研究)设计对潜在参考材料进行可交换性评估:在荷兰“ Calibration 2000”项目框架内的研究

获取原文
           

摘要

Background: The Dutch project “Calibration 2000” aims at harmonization of laboratory results via calibration by development of commutable, matrix-based, secondary reference materials. An alternative approach to the NCCLS EP14 protocol for studying commutability of reference materials is presented, the “twin-study design”, which in essence is a multicenter, split-patient-sample, between-field-methods protocol.Methods: The study consisted of the simultaneous analysis of fresh patient sera and potential reference materials (PRMs) for HDL-cholesterol (HDL-C) by 86 laboratories forming 43 laboratory couples. Six subgroups of method combinations were formed. The patient sera were selected and interchanged by each laboratory couple. The PRMs consisted of three types: C37, prepared according to the NCCLS C37 protocol; Fro, frozen selectively pooled human serum; and Lyo, which was the same serum pool as Fro but lyophilized in the presence of sucrose. All PRMs were provided in three HDL-C concentrations. The regression line residuals for the PRMs were normalized by expressing them as multiples of the state-of-the-art within laboratory SD (SDSA). In addition, the extra contribution of each PRM to the total measurement uncertainty, CVNetto, was calculated.Results: Averaged over the three PRM concentrations, 1.6% of the C37 residuals were outside the 3 SDSA limit. For the Fro and Lyo PRMs, these values were 2.4% and 11.1%. CVNetto values for C37, Fro, and Lyo were 2.9%, 4.3%, and 5.3%, respectively.Conclusions: The present twin-study design, as a practical alternative to the NCCLS EP14 protocol, is a viable way of studying commutability characteristics of PRMs. The study suggests that the C37 PRMs are the best candidates for a future reference material.
机译:背景:荷兰的“ Calibration 2000”项目旨在通过开发可交换的,基于矩阵的辅助参考材料,通过校准来统一实验室结果。提出了一种NCCLS EP14协议的替代方法,用于研究参考材料的可交换性,即“双室研究设计”,其本质上是一种多中心,患者分开样本,场间方法的协议。方法:本研究包括由86个实验室组成的43对实验室同时分析新鲜的患者血清和HDL-胆固醇(HDL-C)的潜在参考材料(PRM)。形成了六个方法组合子组。每个实验室夫妇选择并交换患者血清。 PRM由三种类型组成:根据NCCLS C37协议准备的C37;来回冷冻,选择性汇集人血清;和Lyo,血清与Fro相同,但在蔗糖存在下冻干。所有PRM均以三种HDL-C浓度提供。通过将PRM的回归线残差表示为实验室SD(SDSA)中最新技术的倍数来进行归一化。此外,还计算了每种PRM对总测量不确定度的额外贡献CVNetto。结果:在三个PRM浓度中取平均值,C37残留物的1.6%超出了3 SDSA限制。对于Fro和Lyo PRM,这些值分别为2.4%和11.1%。 C37,Fro和Lyo的CVNetto值分别为2.9%,4.3%和5.3%。结论:目前的双研究设计可作为NCCLS EP14协议的一种实用替代方法,是研究C37的可交换性特征的可行方法。 PRM。研究表明,C37 PRM是未来参考材料的最佳候选者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号