A method for measuring glycated hemoglobin (Hb A1c) and an accompanying method of specimen transport to a central laboratory were developed for the multicenter Diabetes Control and Complications Trial (DCCT). In the DCCT, results for Hb A1c are used to assess chronic glycemic control for data collection and patient management. During the feasibility phase of the trial, central (CHL) and backup laboratories using automated, "high-performance" ion-exchange liquid-chromatographic methods were established. Whole-blood samples were stored (4 degrees C) at each of the 21 clinical centers for up to 72 h before air-express shipment to the CHL. Quality-control procedures included daily analyses of three calibration specimens. A pooled hemolysate was assayed frequently over time as a long-term quality control (LTQC). After 18 months, within- and between-run CVs were less than 6%. Mean values for split duplicate samples assayed in a masked fashion at the CHL were nearly identical. LTQC results indicated no significant assay drift over time. More than 6000 samples were assayed (mean interval between obtaining the blood sample and completing the assay: less than six days). Hb A1c evidently can be precisely and reliably measured in the context of a long-term, multicenter trial such as the DCCT.
机译:针对多中心糖尿病控制和并发症试验(DCCT),开发了一种测定糖化血红蛋白(Hb A1c)的方法以及将标本运送到中心实验室的方法。在DCCT中,Hb A1c的结果用于评估慢性血糖控制,以进行数据收集和患者管理。在试验的可行性阶段,建立了使用自动化的“高性能”离子交换液相色谱方法的中央实验室(CHL)和备用实验室。在将空运到CHL之前,将全血样品在21个临床中心中的每一个中存储(4摄氏度)长达72小时。质量控制程序包括对三个校准样品的每日分析。随着时间的推移,经常对合并的溶血产物进行分析,以作为长期质量控制(LTQC)。 18个月后,运行内和运行间CV小于6%。在CHL处以掩蔽方式分析的重复样品的平均值几乎相同。 LTQC结果表明,随着时间的推移,检测结果没有明显的漂移。化验了6000多个样本(获取血液样本与完成化验之间的平均间隔:少于6天)。在长期的多中心试验(例如DCCT)的背景下,显然可以精确可靠地测量Hb A1c。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号