Inorganic pyrophosphate can be accurately determined in 2 to 4 ml of serum or urine by an ion-exchange method. Pyrophosphate degradation by serum alkaline phosphatase and pyrophosphatase is stopped by adding to the serum 0.1 mmol of dithiothreitol (Cleland's reagent) per liter. This method is suitable for screening large numbers of patients. All of the patients studied who had classical symptoms of active osteogenesis imperfecta also had abnormally high concentrations of pyrophosphate in their serum. Of this group, 62% excreted increased amounts of pyrophosphates in their urine. Seven adults with inactive osteogenesis imperfecta had normal concentrations of inorganic pyrophosphate in their serum, but their urinary excretion of pyrophosphate was abnormally great. Patients undergoing therapy with magnesium oxide or calcitonin had normal values for serum and urine pyrophosphate. Determination of inorganic pyrophosphate concentrations in serum may be helpful in studying the progress of this disease and in monitoring therapy.
机译:无机焦磷酸盐可以通过离子交换法在2-4 ml血清或尿液中准确测定。通过向血清中每升添加0.1 mmol二硫苏糖醇(Cleland's试剂)来停止血清碱性磷酸酶和焦磷酸酶对焦磷酸的降解。此方法适用于筛查大量患者。所有具有活动性成骨不全的典型症状的所有研究患者的血清中都存在异常高浓度的焦磷酸盐。在这一组中,有62%的人尿液中焦磷酸的排出量增加。七个成骨失活不全的成年人的血清中无机焦磷酸盐的浓度正常,但其焦磷酸盐的尿排泄异常高。接受氧化镁或降钙素治疗的患者血清和尿液焦磷酸盐的正常值。测定血清中无机焦磷酸盐的浓度可能有助于研究该病的进展和监测治疗。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号