首页> 外文期刊>Clinical Chemistry: Journal of the American Association for Clinical Chemists >Creatine kinase isoenzyme--antibody reactions in immuno-inhibition and immunonephelometry.
【24h】

Creatine kinase isoenzyme--antibody reactions in immuno-inhibition and immunonephelometry.

机译:肌酸激酶同工酶-免疫抑制和免疫比浊法中的抗体反应。

获取原文
           

摘要

I have raised, in rabbits, antibodies against MM and BB isoenzymes of creatine kinase. The antibodies produced were homogeneous by Ouchterlony double immunodiffusion and did not cross react with their opposite antigens. Both antisera, however, appeared to be mixtures of antibodies, displaying different equivalences for activation, inactivation, and, possibly, precipitation. Inactivation studies indicated the presence of antibodies effective against dimer only and antibodies effective against monomer or dimer. Both antisera cross reacted with MB and displayed antibodies that appeared to block only half of the activity as well as antibodies that blocked all of the activity. The antisera produced were useful for measuring MB by both immuno-inhibition and immunonephelometry, but neither appears to be advantageous over current electrophoresis or ion-exchange methods. A comparison of decay of MB in patients between activity and mass measurements indicated that activity decay is about 12-fold faster than mass decay.
机译:我已经在兔体内产生了针对肌酸激酶的MM和BB同工酶的抗体。产生的抗体通过Ouchterlony双重免疫扩散是均质的,并且不会与其相对抗原发生交叉反应。然而,两种抗血清似乎都是抗体的混合物,显示出不同的激活,失活和可能的沉淀等价物。灭活研究表明存在仅对二聚体有效的抗体和对单体或二聚体有效的抗体。两种抗血清均与MB发生交叉反应,并显示出似乎仅阻断一半活性的抗体以及阻断所有活性的抗体。产生的抗血清可用于通过免疫抑制和免疫比浊法测量MB,但似乎都没有优于当前的电泳或离子交换方法。在患者活动量和质量测量值之间MB衰减的比较表明,活动量衰减比质量衰减快约12倍。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号