Use of cholesterol oxidase for assay of total and free cholesterol in serum by continuous-flow analysis.

机译:使用胆固醇氧化酶通过连续流分析法测定血清中的总胆固醇和游离胆固醇。

获取原文
           

摘要

Idescribe an assay for total cholesterol in serum, with use of the AutoAnalyzer ii (Technicon), in which cholesterol esters are saponified by alkali, cholesterol is held in aqueous micellar solution with a surfactant (Triton X-100) and oxidized by cholesterol oxidase, and the hydrogen peroxide produced is measured by chelation with Ti4+ and xylenol orange. An assay for free cholesterol in serum, based on similar principles, is also described, and the two can be run simultaneously on a dual-channel AutoAnalyzer II. Standard solutions of cholesterol in isopropanol have poorer carryover characteristics than sera, and therefore do not reach the same continuous-flow steady state as sera of equivalent concentrations. Consequent potential calibration errors are avoided by using micellar solutions of cholesterol containing albumin for standardization. The formation of cholesterol peroxide in solutions of cholesterol in isopropanol is demonstrated, and this constitutes another potential source of error in the calibration of enzymic cholesterol assays. In analyzing patients' sera, results of the total cholesterol assay correlate well with those of a mechanized method in which cholesterol esterase and cholesterol oxidase are used; an automated Abell method, calibrated with solutions of cholesterol in isopropanol, gave slightly higher values. Determinations of the ratio of free cholesterol to total cholesterol by our automated cholesterol exidase assays given values that agree well with published results in which digitonin precipitation is used.
机译:使用AutoAnalyzer ii(Technicon)描述血清中总胆固醇的测定方法,其中胆固醇酯被碱皂化,胆固醇与表面活性剂(Triton X-100)结合在胶束水溶液中,并被胆固醇氧化酶氧化,生成的过氧化氢通过与Ti4 +和二甲苯酚橙螯合来测量。还介绍了基于类似原理的血清中游离胆固醇测定方法,两者可以在双通道AutoAnalyzer II上同时运行。胆固醇在异丙醇中的标准溶液比血清具有较差的残留特性,因此不能达到与等浓度血清相同的连续流动稳态。通过使用含有白蛋白的胆固醇的胶束溶液进行标准化,可以避免潜在的校准错误。已证明在异丙醇中的胆固醇溶液中会生成过氧化胆固醇,这构成了酶促胆固醇测定校准中另一个潜在的误差来源。在分析患者的血清时,总胆固醇测定的结果与使用胆固醇酯酶和胆固醇氧化酶的机械化方法的结果非常相关。用胆固醇在异丙醇中的溶液校准的自动Abell方法得出的值略高。通过我们的自动胆固醇外切酶测定法测定游离胆固醇与总胆固醇的比率,所给出的值与使用洋地黄皂苷沉淀的公开结果非常吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号