首页> 外文期刊>Bulletin of the Korean Chemical Society >A Simple and Sensitive High Performance Liquid Chromatography-Electrospray Ionization/Mass Spectrometry Method for the Quantification of Ethyl Pyruvate in Rat Plasmac
【24h】

A Simple and Sensitive High Performance Liquid Chromatography-Electrospray Ionization/Mass Spectrometry Method for the Quantification of Ethyl Pyruvate in Rat Plasmac

机译:一种简单灵敏的高效液相色谱-电喷雾电离/质谱法定量大鼠血浆中的丙酮酸乙酯

获取原文
获取外文期刊封面目录资料

摘要

Ethyl pyruvate (EP) is known as a scavenger of reactive oxygen species (ROS) in the body through its role in the donation of diketone groups to metals to form an EP-metal complex. In order to develop a method for the quantification of EP in biological media, a sensitive and specific, high-performance liquid chromatographyelectrospray ionization-mass spectrometry (HPLC-ESI/MS) method is used to determine the EP-alkali metal ion binding species. The analyte was separated on a ZORBOX SB-C8 (3.5 μm, 30 mm × 2.1 mm I.D.) column and analyzed in selected ion monitoring (SIM) mode with a positive ESI interface using the m/z 255 [2M + Na]+ ion. The method was validated over the concentration range of 0.5-60.0 μg/mL under 1/9 (v/v) of acetonitrile/methanol solvent system with flow rate 0.05 mL/min. The limit of quantification (LOQ) was 0.5 μg/mL.
机译:丙酮酸乙酯(EP)通过将二酮基团捐赠给金属以形成EP-金属络合物而在体内被称为活性氧(ROS)的清除剂。为了开发一种定量生物介质中EP的方法,使用了灵敏而高效的高效液相色谱电喷雾电离质谱(HPLC-ESI / MS)方法来确定EP碱金属离子结合物种。在ZORBOX SB-C8(3.5μm,30 mm×2.1 mm ID)色谱柱上分离分析物,并使用m / z 255 [2M + Na] +离子在具有正ESI界面的选定离子监测(SIM)模式下进行分析。在乙腈/甲醇溶剂系统的1/9(v / v)下,流速为0.05 mL / min的情况下,在0.5-60.0μg/ mL的浓度范围内验证了该方法。定量限(LOQ)为0.5μg/ mL。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号