首页> 外文期刊>Bulletin of the Korean Chemical Society >Destruction and Removal of PCBs in Waste Transformer Oil by a Chemical Dechlorination Process
【24h】

Destruction and Removal of PCBs in Waste Transformer Oil by a Chemical Dechlorination Process

机译:通过化学脱氯工艺销毁和去除废变压器油中的多氯联苯

获取原文
获取外文期刊封面目录资料

摘要

A practical and efficient disposal of PCBs (polychlorinated biphenyls) in waste transformer oil by a chemical dechlorination process has been reported. The transformer oil containing commercial PCB mixtures (Aroclor 1242, 1254 and 1260) was treated by the required amounts of PEG 600 (polyethylene glycol 600), potassium hydroxide (KOH) and aluminum (Al), along with different reaction temperatures and times. The reaction of PEG with PCBs under basic condition produces arylpolyglycols, the products of nucleophilic aromatic substitution. The relative efficiencies of PCB treatment process were assessed in terms of destruction and removal efficiency (DRE, %). Under the experimental conditions of PEG600/KOH/Al/100 oC/2hr, average DRE of PCBs was approximately 78%, showing completely removal of PCBs containing 7-9 chlorines on two rings of biphenyl which appear later than PCB no. 183 (2,2`,3,4,4`,5`,6-heptaCB) in retention time of GC/ECD. However, when increasing the reaction temperature and time to 150 oC and 240 min, average DRE of PCBs including the most toxic PCBs (PCB no. 77, 105, 118, 123 and 169) in PCB family reached 99.99% or better, with the exception of PCB no. 5 and 8 (2,3-diCB and 2,4`-diCB). In studying the reaction of PEG with PCBs, it confirmed that the process led to less chlorinated PCBs through a stepwise process with the successive elimination of chlorines. The process also permits complete recovery of treated transformer oil through simple segregating procedures.
机译:据报道,通过化学脱氯工艺可以切实有效地处理废变压器油中的多氯联苯(多氯联苯)。用所需量的PEG 600(聚乙二醇600),氢氧化钾(KOH)和铝(Al)以及不同的反应温度和时间处理含商用PCB混合物(Aroclor 1242、1254和1260)的变压器油。 PEG与PCB在碱性条件下的反应会生成芳基聚乙二醇,这是亲核芳族取代的产物。根据销毁和清除效率(DRE,%)评估了PCB处理工艺的相对效率。在PEG600 / KOH / Al / 100 oC / 2hr的实验条件下,PCB的平均DRE约为78%,显示出联苯两个环上含7-9个氯的PCB的完全去除,其出现时间晚于PCB No.。 GC / ECD保留时间为183(2,2`,3,4,4`,5`,6-heptaCB)。但是,当将反应温度和时间提高到150 oC和240分钟时,包括PCB系列中毒性最高的PCB(PCB号为77、105、118、123和169)的PCB的平均DRE达到99.99%或更高, PCB号除外5和8(2,3-diCB和2,4`-diCB)。在研究PEG与PCBs的反应时,证实了该过程通过逐步消除氯的逐步过程,导致了较少的氯化PCB。该方法还可以通过简单的分离程序完全回收处理过的变压器油。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号