This paper describes an inductively coupled plasa emission spectrometric method for the analysis of Fe in fat plasma. Calibration curves were obtained in the range of 0.125-1.50 Ф·mL-1. The relative standard deviation ranges from 5.93% to 6.80% and accuracy was between 87.6 and 102.0%. Dilution with water had no influence on the performance of the method, which could then be used to quantify Fe concentration in plasma up to 0.50 Ф·mL-1. The limit of quantification was 0.10 Ф·mL-1. At this level, the average relative standard deviation was 6.8%. The results indicate that the method meets the accuracy and precision requirements for the pharmacokinetic studies. The Fe concentration in rat plasma was measured and the main pharmacokinetic parameters were calculated by Topfit 2.0 (GmbH. shering AG, Godecke AG, Germany).
机译:本文介绍了一种电感耦合等离子体发射光谱法,用于分析脂肪血浆中的铁。在0.125-1.50Ф·mL -1 的范围内获得校准曲线。相对标准偏差范围为5.93%至6.80%,准确度为87.6至102.0%。用水稀释对方法的性能没有影响,可用于定量分析血浆中高达0.50Ф·mL -1 的Fe浓度。定量限为0.10Ф·mL -1 。在这个水平上,平均相对标准偏差为6.8%。结果表明该方法满足药代动力学研究的准确性和精密度要求。测量大鼠血浆中的铁浓度,并通过Topfit 2.0(GmbH.shering AG,Godecke AG,德国)计算主要药代动力学参数。