Objective Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. Setting All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. Primary and secondary outcome measures Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. Results The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. Conclusions The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice.
机译:目的市面上有各种现场护理测试(POCT)尿液分析仪可用于常规的常规尿液分析。本研究比较了一般实践中用于诊断尿路感染的六种不同POCT尿液分析仪的分析性能,一致性和用户友好性。设置所有测试程序均在荷兰的初级保健诊断中心进行。尿液样本是按四种常规方法收集的。主要结果指标和次要结果指标POCT分析仪对亚硝酸盐,白细胞和红细胞的分析性能和与实验室参考标准的一致性是主要结果指标,并通过计算敏感性,特异性,阳性和阴性预测值以及Cohenκ系数进行分析达成协议。次要结果指标是POCT分析仪的用户友好性,以及分析仪的其他特征。结果对以下六种POCT分析仪进行了评估:Uryxxon Relax(Macherey Nagel),Urisys 1100(Roche),Clinitek Status(西门子),Aution 11(Menarini),Aution Micro(Menarini)和Urilyzer(Analyticon)。分析性能对所有分析人员都很好。与实验室参考标准相比,总体一致性良好,但每个参数和每个分析仪均不同。关于亚硝酸盐测试,这是临床实践中最重要的测试,除一项测试外,其他均与实验室标准完全吻合。对白细胞和红细胞的特异性很高,但敏感性却很低。白细胞的一致性在良好与非常好之间变化,而红细胞测试的一致性在良好与良好之间。初次使用者表示分析仪易于使用。他们期望在日常实践中使用这些分析仪时能够提高生产率和准确性。结论所有六种市售的POCT尿液分析仪的总体性能和用户友好性足以证明常规实践中常规使用可疑尿路感染。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号