Manufacturing of miniaturized high activity 192Ir sources have been made a market preference in modern brachytherapy. The smaller dimensions of the sources are flexible for smaller diameter of the applicators and it is also suitable for interstitial implants. Presently, miniaturized 60Co HDR sources have been made available with identical dimensions to those of 192Ir sources. 60Co sources have an advantage of longer half life while comparing with 192Ir source. High dose rate brachytherapy sources with longer half life are logically pragmatic solution for developing country in economic point of view. This study is aimed to compare the TG-43U1 dosimetric parameters for new BEBIG 60Co HDR and new microSelectron 192Ir HDR sources. Dosimetric parameters are calculated using EGSnrc-based Monte Carlo simulation code accordance with the AAPM TG-43 formalism for microSlectron HDR 192Ir v2 and new BEBIG 60Co HDR sources. Air-kerma strength per unit source activity, calculated in dry air are 9.698×10-8 ± 0.55% U Bq-1 and 3.039×10-7 ± 0.41% U Bq-1 for the above mentioned two sources, respectively. The calculated dose rate constants per unit air-kerma strength in water medium are 1.116±0.12% cGy h-1U-1 and 1.097±0.12% cGy h-1U-1, respectively, for the two sources. The values of radial dose function for distances up to 1 cm and more than 22 cm for BEBIG 60Co HDR source are higher than that of other source. The anisotropic values are sharply increased to the longitudinal sides of the BEBIG 60Co source and the rise is comparatively sharper than that of the other source. Tissue dependence of the absorbed dose has been investigated with vacuum phantom for breast, compact bone, blood, lung, thyroid, soft tissue, testis, and muscle. No significant variation is noted at 5 cm of radial distance in this regard while comparing the two sources except for lung tissues. The true dose rates are calculated with considering photon as well as electron transport using appropriate cut-off energy. No significant advantages or disadvantages are found in dosimetric aspect comparing with two sources.Keywords: BEBIG Co-60 HDR source, comparison of Ir-192 and Co-60, EGSnrc, HDR brachytherapy, microslectron Ir-192, Monte Carlo code
机译:在现代近距离放射治疗中,制造小型化的高活性192Ir放射源已成为市场的首选。放射源的较小尺寸对于较小的施药器直径是柔性的,并且还适用于间隙植入物。目前,小型化的60Co HDR光源已经可以提供与192Ir光源相同的尺寸。与192Ir光源相比,60Co光源的半衰期更长。从经济角度看,高剂量率近距离放射疗法源具有更长的半衰期,这在逻辑上是发展中国家的务实解决方案。这项研究旨在比较新型BEBIG 60Co HDR和新型microSelectron 192Ir HDR光源的TG-43U1剂量参数。剂量参数是使用基于EGSnrc的蒙特卡罗模拟代码,根据AAPM TG-43形式,用于MicroSlectron HDR 192Ir v2和新的BEBIG 60Co HDR源。对于上述两个来源,在干燥空气中计算的每单位源活动的空气比释动能强度分别为9.698×10-8±0.55%U Bq-1和3.039×10-7±0.41%U Bq-1。对于两种来源,在水介质中每单位气释力强度的计算剂量率常数分别为1.116±0.12%cGy h-1U-1和1.097±0.12%cGy h-1U-1。对于BEBIG 60Co HDR光源,在最大距离为1 cm且大于22 cm的情况下,径向剂量函数的值高于其他光源。各向异性值在BEBIG 60Co辐射源的纵向侧急剧增加,并且其上升比其他辐射源的急剧上升。已经用真空幻影对乳房,致密骨,血液,肺,甲状腺,软组织,睾丸和肌肉的吸收剂量的组织依赖性进行了研究。在比较两个来源(肺组织除外)的情况下,在径向距离5 cm处没有发现明显变化。实际剂量率是在考虑了光子以及使用适当截止能量的电子传输的情况下计算的。与两个来源相比,在剂量学方面没有发现明显的优缺点。关键词:BEBIG Co-60 HDR来源,Ir-192和Co-60的比较,EGSnrc,HDR近距离放射治疗,微电子Ir-192,蒙特卡洛代码

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号