首页> 外文期刊>Journal of Medical Microbiology: An Official Journal of the Pathological Society of Great Britain and Ireland >D-Zone test for detection of inducible clindamycin resistance using SirScan paper disks and Rosco Neo-Sensitabs at 25 and 15 mm distances
【24h】

D-Zone test for detection of inducible clindamycin resistance using SirScan paper disks and Rosco Neo-Sensitabs at 25 and 15 mm distances

机译:使用SirScan纸盘和Rosco Neo-Sensitab在25和15 mm距离处进行D区测试,以检测诱导型克林霉素耐药性

获取原文
       

摘要

Clindamycin is a possible antibiotic treatment of infections by Gram-positive cocci. However, its use can be limited by inducible clindamycin resistance. To screen for the presence of this type of resistance, the D-zone test is used. The aim of this study was to compare the performance of SirScan paper disks with that of Rosco Neo-Sensitabs for the D-zone test at distances according to dispensers provided by the manufacturers (25 mm) and when the disks are placed at a distance of 15 mm. We studied 364 Gram-stain-positive cocci representing clinical isolates that were resistant to erythromycin and susceptible to clindamycin. Out of these isolates, 207 (57 %) gave a positive D-zone test result at 25 mm distance using SirScan paper disks. When the test was repeated with the same disks placed 15 mm from the 157 (43 %) isolates that had previously given a negative result, 58 (36.9 %) gave a positive D-zone test result. The same isolates were also found to test positive when Rosco Neo-Sensitabs were used. Placing the disks at a distance of 15 mm instead of 25 mm led to an 84.3 % increase in positive D-tests among Staphylococcus aureus, 43.8 % among group B streptococci (GBS) and 6.4 % among coagulase-negative staphylococci (CNS). In conclusion, the SirScan paper disks are equivalent to Rosco Neo-Sensitabs in screening for inducible resistance to clindamycin. The D-test needs to be performed at a shorter distance (15 mm) to prevent false-negative reporting.
机译:克林霉素可能是革兰氏阳性球菌感染的抗生素治疗方法。但是,其使用可能受到诱导的克林霉素耐药性的限制。为了筛选是否存在这种类型的电阻,使用了D区测试。这项研究的目的是根据制造商提供的分配器(25毫米)以及将磁盘放置在一定距离下时,将SirScan纸盘与Rosco Neo-Sensitab纸在D区测试中的性能进行比较,以进行D区测试。 15毫米我们研究了代表临床分离株的364革兰氏阳性球菌,这些分离株对红霉素具有耐药性,并对克林霉素敏感。在这些分离物中,使用SirScan纸盘在25毫米距离处有207个(57%)的D区检测结果为阳性。当使用相同的圆盘重复进行测试时,距离之前给出阴性结果的157个分离株(43%)分离15毫米,而58个样品(36.9%)给出了阳性D区测试结果。当使用Rosco Neo-Sensitabs时,也发现相同的分离物测试呈阳性。将磁盘放置在15毫米而不是25毫米的距离处,导致金黄色葡萄球菌阳性D检验增加84.3%,B组链球菌(GBS)中增加43.8%,凝固酶阴性葡萄球菌(CNS)中增加6.4%。总之,SirScan纸盘在筛选出对克林霉素的诱导抗性方面与Rosco Neo-Sensitabs相当。 D测试需要在更短的距离(15毫米)处执行,以防止出现假阴性报告。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号